Dataman 448PRO2 User Manual page 104

Table of Contents

Advertisement

5. Device verification
6. Operation result check.
This is fully managed by PG4UW control program. Serialization generator does not have to
do any operation according to operation result. Control program will call serialization
generator with required command line parameters.
OK - PG4UW makes request for next serial number. Next serial number was read from
.dat file in step 3. Call of serialization generator will have next serial number specified in
command line.
ERROR - PG4UW does not make request for new serial number. Recent serial number
will be used for next device. Next call of serialization generator will have recent serial
number specified in command line.
7. Repeat programming with next device?
Yes
go to step 2.
No
continue at step 8.
8. End of programming batch
Notes:
In case of error programming result, recent serial number is used, but generator will be
called at step 3. anyway, even if the same number is used as for previously programmed
device.
If error of serialization .dat file is detected, program PG4UW reports serialization error and
stops continuing of programming batch immediately.
Device / Device options / Statistics
Statistics gives the information about actual count of device operations, which were proceeded
on selected type device. If one device is corresponding to one device operation, e.g.
programming, the number of device operations will be equal to number of programmed
devices.
The next function of statistics is Count down. Count down allows checking the number of
device operations, and then number of devices, on which device operations have to be done.
After each successful device operation the value of count down counter is decremented. Count
down has user defined start number of devices to do. When count down value reach zero, it
means, specified number of devices is complete and user message about complete count
down will be displayed.
Statistics dialog contains following options:
Check boxes Program, Verify, Blank, Erase and Read define operations, after which
statistics values increment.
Any selected and performed device operation will increment the Total counter and one of
Success or Failure counters depending on device operation result (success or failure).
A combination of partial operations is counted as one operation only. For example, a Read
operation including Verify after Read is one operation. A Program operation including Erase
and/or Verify operations is counted as one operation.
Check box Count down sets Count down activity (enable or disable). Edit box following the
Count down check box defines initial number of count down counter, from which count down
starts.
104

Advertisement

Table of Contents
loading

This manual is also suitable for:

48pro248pro2c40pro

Table of Contents