<ordnum> is decimal order of the file. If there are any report files with the same name, then
order for new report file is incremented about order of existing files.
<prjname> is project file name of recently used project, and without the project file name
extension.
Example 1:
Let's use the project file c:\myproject.eprj and directory for Job Report set to d:\job_reports\.
There are no report files present in the Job Report directory.
The final Job Report file name will be:
d:\job_reports\job_report_000_myproject.jrp
Example 2:
Let's use the conditions from Example 1, but assume there is already one report file present.
Name of this file is d:\job_reports\job_report_000_myproject.jrp
The final Job Report file name of new report will be:
d:\job_reports\job_report_001_myproject.jrp
Note: The order inside file name is incremented by 1.
When Automatically save Job Report file setting is set, no Job Report dialogs appears when
generating Job Report. Newly generated Job Report is saved to file without any dialogs or
messages (if no error occurs while saving to file).
If the checkbox Automatically save Job Report file is unchecked, the PG4UW will show Job
Report dialog every time needed.
In the Job Report dialog user can select operation to do with Job Report. If user selects no
operation (Close button), the Job Report will be written to PG4UW Log Window only.
Automatic YES!
Allows user to override default settings (as preset in PG4UW software) of indication for the
state when the programmer and the software wait for withdrawing programmed device and a
new one will be inserted in active Automatic YES! mode.
Default (as preset in software) - the programmer indicates the state when a device is
programmed and the programmer with software wait for inserting a new device as preset in the
software for respective programmer. Multi-sockets programmers (the programmers with more
than one ZIF socket) do not indicate this state; see description for Not indicated (quiet
mode). Single-socket programmers (the programmers with one ZIF socket) indicate this state
by LED Busy blinking; see description for By LED Busy blinking setting.
Not indicated (quiet mode) – the programmer, regardless of the number of ZIF sockets of the
programmer, does not indicate the state when a device is programmed and the programmer
with software wait for inserting a new device. After an operation with a device only one of the
status LEDs Error or OK lights, in dependence on the result of previous operation. This LED
goes off immediately after detecting removal of a device from the ZIF socket.
By LED Busy blinking - the programmer, regardless of the number of ZIF sockets of the
programmer, indicates the state when a device is programmed and the programmer with
software wait for inserting a new device mode by blinking with the LED Busy. After an
operation with a device is done, one of the status LEDs (OK or Error) lights, in dependence on