Maintenance - Dataman 448PRO2 User Manual

Table of Contents

Advertisement

Maintenance

We recommend following the instructions and precautions herein to achieve high reliability of
the programmer for a long period of time.
The programmer maintenance depends on character and amount of its use. Regardless, the
following recommendations are generally accepted:
Do not use and store the programmer in dusty places.
Humidity accelerates sedimentation of debris and dust in ZIF socket.
After end the job cover the ZIF socket of the programmer with enclosed dust cover.
Do not expose the programmer to direct sunlight or position near a source of heat.
Intensively daily use (programming centre, production)
Daily maintenance
Check the ZIF sockets of the programmer and the socket converters for their condition and
wear. Remove debris, dust and grime from the ZIF sockets with clean, dry and compressed
air. Clean the ZIF sockets both in closed and opened position.
Weekly maintenance
Perform the Selftest for every programmer or programming module.
Quarterly maintenance
Gently clean the surface of the programmer with isopropyl alcohol or technical alcohol on a
soft cloth. The LCD clean with a soft cloth moistens in water only. Isopropyl alcohol may
damage surface of the LCD.
Perform the calibration test if the programmer supports this feature.
Daily use (developing laboratory, office)
Daily maintenance
After end of the job cover the ZIF socket of the programmer with enclosed dust cover. It is also
recommended to protect the ZIF sockets of the socket converters from dust and grime.
Weekly maintenance
Check the ZIF sockets of the programmer and the socket converters for their condition and
wear. Remove debris, dust and grime from the ZIF sockets with clean, dry and compressed
air. Clean the ZIF sockets both in closed and opened position.
Quarterly maintenance
Perform the Selftest for every programmer or programming module.
Biannual maintenance
Gently clean the surface of the programmer with isopropyl alcohol or technical alcohol on a
soft cloth. The LCD clean with a soft cloth moistens in water only. Isopropyl alcohol may
damage surface of the LCD.
Perform the calibration test if the programmer supports this feature.
Occasional use
Daily maintenance
After end of the job cover the ZIF socket of the programmer with enclosed dust cover. It is also
recommended to protect the ZIF sockets of the socket converters from dust and grime.
Quarterly maintenance
Check the ZIF sockets of the programmer and the socket converters for their condition and
wear. Remove debris, dust and grime from the ZIF sockets with clean, dry and compressed
air. Clean the ZIF sockets both in closed and opened position.
152

Advertisement

Table of Contents
loading

This manual is also suitable for:

48pro248pro2c40pro

Table of Contents