HYOSUNG NH-2700 Operator's Manual page 38

Hide thumbs Also See for NH-2700:
Table of Contents

Advertisement

NH-2700
Turn the dial to the left (CCW) until
is displayed
8)
-> Press #8 -> EcF
Press the "#" button followed by the "8" button. EcF (Enter current Factory combination) will be
displayed.
9) EcF -> Enter Current Shelved Mode Combination -> EnF
Enter the current shelved mode combination, "EnF" (Enter new Factory combination) will be
displayed.
10) EnF -> Enter New Combination -> Cnf
Select and enter the new combination. "CnF" (confirm new Factory combination) will be displayed
11) Cnf -> Enter New Combination -> POC
Enter new combination again to confirm. POC (Pull Out Change key) will be displayed.
12) POC -> Remove Change Key -> EOP
Remove the change key. EOP (End Operation) is displayed.
13) EOP -> Power Lock -> EC
Turn the dial to the left (CCW) until EC (Enter Combination) is displayed.
14) EC -> Enter New Shelved Mode Combination -> OPr
Enter the new shelved mode combination by pressing those digits on the lock's keypad. The
numbers will be displayed on the LCD as they are entered
15) OPr -> Retract Bolt
Turn the Dial to the right (CW) to retract the bolt.
16) Close Door
17) Extend Bolt
Turn the Dial to the left (CCW) to extend the bolt.
(the Change Key symbol along with Enter Combination)