5.8.8.3 CLEAR NVRAM
To clear NVRAM on the NH-2700, begin by entering the Operator Function Menu using the Master
Password. Then enter SYSTEM SETUP, SYSTEM CONTROL and CLEAR NVRAM in sequence.
1) CLEAR ALL
This will delete all programmed parameters and make all setting information (including passwords) to
the default settings. This does NOT include the master keys which are stored in EPP.
2) CLEAR SETTING
This will delete all programmed parameters and make all information (including passwords) to the
default settings. This does NOT include the master keys which are stored in EPP, denomination,
journal data.
3) CLEAR JOURNAL
This will delete all journal data permanently
4) CLEAR TRANS. SEQUENCE NO.
This function will reset the journal sequence number to <0000>. This may be useful if you switch
processing or switch Terminal ID numbers and want to keep new records.
5) CLEAR LOG
This will delete all logs permanently
NOTE: Be careful when using these features (NVRAM clearing) – The initialized data can NOT be
recovered.