HYOSUNG NH-2700 Operator's Manual page 226

Hide thumbs Also See for NH-2700:
Table of Contents

Advertisement

NH-2700
Error Code
(DISPENSE) Dispense the notes on the state
40088
of unsupported denomination setting.
CS13 sensor detects a bill with hole during
4008F00
dispensing
40090
Decryption Error / Key Error
Receive CMD except certification on the status
40091
of non-certification.
40092
Encryption Chip Communication Error
0xC1 Command Execution Error (Certification
40093
Fail)
0xC2 Command Execution Error (Certification
40094
Fail)
CS31AB~CS13 Time out(Jam) during
4009A00
dispensing from 3rd cassette.
Trying to dispense bills from 3rd cassette but
4009D00
the 3rd cassette doesn't installed.
4009F00
3 cassette miss feed error
Something is detected on CS2 sensor after
400AC00
dispense operation
Communication error - Command Length
400BC00
doesn't match.
400BD
(Set CDU Info) CDU Type Setting Error
(DISPENSE) Jam on the transport during
400BE
operation (CS4 A/B Dark)
Bill pickup sensor(CS1, CS15) recognized has
400BE00
a hole and CS4 sensor detects it or CS4
snesor detects the gap too close
(Initialize, Dispense) No Encoder Signal 150ms
400BF
or more during operation.
Description
7- 15
7. Appendix
Trouble shooting