7. Place the heat sink on the processor and press the base of the heat sink until the retaining clip locks onto the heat sink at all
the four corners.
CAUTION:
To avoid damaging the fins on the heat sink, do not press down on the heat sink fins.
NOTE:
● Ensure latching features on retaining clip and heat sink are aligned during assembly.
● Ensure that the pin 1 indicator on the heat sink is aligned with the pin 1 indicator on the retaining clip before placing
the heat sink onto the retaining clip.
Figure 63. Installing the heat sink onto the processor
Next steps
1. Install the heat sink module or Install the liquid cooling module.
2.
Replace the air
shroud.
3. Follow the procedure listed in

Expansion cards and expansion card risers

NOTE:
A system event entry is logged in the iDRAC Lifecycle Controller if an expansion card riser is not supported or
missing. It does not prevent your system from turning on. However, if a F1/F2 pause occurs with an error message,
see Troubleshooting expansion cards section in the Dell EMC PowerEdge Servers Troubleshooting Guide at
www.dell.com/poweredgemanuals.
After working inside your
system.
Installing and removing system components
https://
69