POWER SWITCH
• Open the water mains valve.
• Turn the power switch to position "1" (elec-
tricity is supplied to the pump to automati-
cally fill up the appliance's heating unit and
steam heating unit) and wait for the heating
unit to be automatically filled with water.
• Turn the main switch to position "2" (full electricity is sup-
plied, including to the heating element in the heating
unit) and wait for the machine to warm up completely.
6.3.2
Electric heating (versions with
Display)
• Press the machine's main switch (1).
1
• Wait for the heating unit to be automatically filled with
water, if necessary.
• Wait another second or so for the automatic test to be
carried out.
FUNCTIONAL TEST
TEST RESULTS
• The machine is ready for use when the following mes-
sages appear on the display:
1.0 BAR
09:16
Heating unit
Heating unit
pressure
temperature
1.0 BAR
09:16
09-10-12 5
Time
See the days of the week reference table in para-
graph "Programming a Working Day" on page 54.
46
216
of
1
WAIT
- OK -
120°C
09-10-12 5
Programming
indicator
120°C P
Date
Day of the week
If the temperature inside the heating unit is lower
than 90°C (machine's heating-up phase), the mes-
0
sage LOW will appear on the display.
2
To restart the machine, press and hold the same buttons for
3 seconds.
Gas heating (if a gas system
6.3.3
has been installed)
• Turn the power switch (A) to position 1.
• Open the gas valve (B) on the mains.
• Press and hold the button (C) and simultaneously press
the ON button (D). Once the flame has ignited, hold down
the knob (C) for a few seconds, to allow the thermocouple
to activate correctly.
• Then check that the flame has ignited through the win-
dow (E).
• Wait for the operating pressure shown on the pressure
gauge to reach the working value of 0.1-0.12 MPa (1-1.2
bar).
C
D
A
Electric + gas heating (if a gas
6.3.4
system has been installed)
During the machine's heating-up phase (roughly
20 minutes), the negative pressure valve will re-
lease steam for a few seconds until the valve closes.
Do not open the gas mains when the heating unit is empty.
• Proceed as indicated in the previous paragraph.
• After checking that the flame has ignited, turn the power
switch (A) to position 2. In this way the heating unit's
heating element is powered and the operating pressure
will be reached more quickly.
• Wait for the operating pressure shown on the pressure
gauge to reach the working value of 0.1-0.12 MPa (1-1.2
bar).
6.3.5

Turning off the machine

Turn off the machine using the main switch or power switch.