The CR10 is programmed to measure the thermocouple temperature every sixty seconds. The
If Time instruction sets the Output Flag at the beginning of every hour. Next, the Output
Instructions for time and average are added.
04:P77
05:P71
Instruction #
(Loc.:Entry)
06:P92
07: P77
08: P73
SAMPLE PROGRAM 2
Parameter
(Par#:Entry)
Description
Enter Program Table 1
60 second (1 minute) execution interval
01:P00
Erase previous Program before
continuing.
Measure internal temperature
01:1
Store temp in Location 1
Measure thermocouple temperature
01:1
1 repetition
02:1
Range code (2.5 mV, slow)
03:5
Input channel of TC
04:1
TC type: copper-constantan
05:1
Reference temp is stored in Location 1
06:2
Store TC temp in Location 2
07:1
Multiplier of 1
08:0
No offset
Parameter
Par.#:Entry)
Description
If Time instruction
01:0
0 minutes into the interval
02:60
60 minute interval
03:10
Set Output Flag 0
Output Time instruction
01:110
Store Julian day, hour, and minute
Average instruction
01:1
one repetition
02:2
Location 2 - source of TC temps. to be
averaged
Parameter
(Par.#:Entry)
Description
If Time instruction
01:0
0 minutes into the interval
02:1440
1440 minute interval (24 hrs.)
03:10
Set Output Flag 0
Output Time instruction
01:100
Store Julian day
Maximize instruction
01:1
One repetition
02:10
Output time of daily maximum in hours and minutes
03:2
Data source is Input Storage Location 2.
CR10 OVERVIEW
OV-19