*** 43 ABS(X) ***
FUNCTION
Take the absolute (ABS) value of X and place
the result in an input location.
PARAM.
DATA
NUMBER
TYPE
01:
4
02:
4
Input locations altered:
*** 44 FRACTIONAL VALUE ***
FUNCTION
Take the fractional (FRAC) value (i.e., the non-
integer portion) of X and place the result in an
input location.
PARAM.
DATA
NUMBER
TYPE
01:
4
02:
4
Input locations altered:
*** 45 INTEGER VALUE ***
FUNCTION
Take the integer (INT) value of X and place the
result in an input location.
PARAM.
DATA
NUMBER
TYPE
01:
4
02:
4
Input locations altered:
*** 46 X MOD F ***
FUNCTION
Do a modulo divide of X by F and place the
result in an input location. X MOD F is defined
as the REMAINDER obtained when X is divided
by F (e.g., 3 MOD 2 = 1). X MOD 0 returns X.
DESCRIPTION
Input location of X
[X]
Dest. input location for
ABS(X)
[Z]
1
DESCRIPTION
Input location of X
[X]
Dest. input location for
FRAC(X)
[Z]
1
DESCRIPTION
Input location of X
[X]
Dest. input location for
INT(X)
[Z]
1
SECTION 10. PROCESSING INSTRUCTIONS
PARAM.
DATA
NUMBER
TYPE
01:
4
02:
FP
03:
4
Input locations altered:
*** 47 X
FUNCTION
Raise X to the Y power and place the result in
an input location.
PARAM.
DATA
NUMBER
TYPE
01:
4
02:
4
03:
4
Input locations altered:
*** 48 SIN(X) ***
FUNCTION
Calculate the sine of X (X is assumed to be in
degrees) and place the result in an input
location. The cosine of a number can be
obtained by adding 90 to the number and taking
the sine (COSX = SIN (X + 90)).
PARAM.
DATA
NUMBER
TYPE
01:
4
02:
4
Input locations altered:
*** 49 SPATIAL MAXIMUM ***
FUNCTION
Find the spatial maximum (SPA MAX) value of the
given set or SWATH of input locations and place
the result in an input location. To find the input
location where the maximum value occurs, add
1000 to the input location number destination
selected [Z] and enter this modified location
number as Parameter 03. The input location ID of
the maximum value observed will then be stored in
destination [Z] plus 1.
DESCRIPTION
Input location of X
[X]
Fixed divisor
[F]
Dest. input loc. For X
MOD F
[Z]
1
Y
***
DESCRIPTION
Input location of X
[X]
Input location of Y
[Y]
Dest. input location for
Y
X
[Z]
1
DESCRIPTION
Input location of X
[X]
Dest. input location for
SIN(X)
[Z]
1
10-3