Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
Requirements and connection to evaluation devices ............Installation ..........................Adjustment ..........................Periodic test ........................... Dimensions in mm ......................... Technical details ........................Safety characteristic data ......................Order reference ........................System ............................Accessories ..........................EC declaration of conformity ....................Operating Manual PSEN ma1.1p-12 22190-EN-04...
PSEN ma1.1p-12 Introduction Validity of documentation This documentation is valid for the product PSEN ma1.1p-12. It is valid until new document- ation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
If installed in other environments, measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to in- terference. Operating Manual PSEN ma1.1p-12 22190-EN-04...
Disposal In safety-related applications, please comply with the mission time T in the safety-related characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSEN ma1.1p-12 22190-EN-04...
If the actuator is within the response range (safety gate closed), the safety contacts of the safety switch are closed. The safety switch is designed for applications in series connections. Operate the PSEN ma1.1p-12 in conjunction with the following components: Actuator PSEN 1.1-10 (see Order reference [...
= Max. overall cable resistance (see evaluation device's technical details) lmax Ri = Internal resistance sensor (see Technical details [ 16]) / km = Cable resistance/km of the cable (see technical details cable) l Ensure the wiring and EMC requirements of EN 60204-1 are met. Operating Manual PSEN ma1.1p-12 22190-EN-04...
Requirements and connection to evaluation devices For use of PSEN ma1.1p-12 in accordance with DIN EN 60947-5-3 an evaluation device must be connected. Connect the PSEN ma1.1p-12 either with a certified Pilz evaluation device or with an evaluation device with defined properties...
Page 11
[ of PSEN ma1.1p-12 – Always comply with the max. switching current safety contacts of PSEN ma1.1p-12. Outputs at the evaluation device must only be switched on again when both reed con- tacts at the safety switch have been opened and closed (partial operation lock)
Page 12
33 34 43 44 21 22 31 32 41 11 12 11 12 21 22 33 34 43 44 PSENmag Fig.: Dual-channel connection of four PSENmag to the input circuits of an evaluation device Operating Manual PSEN ma1.1p-12 | 12 22190-EN-04...
Page 13
PSEN ma1.1p-12 Examples for connection to Pilz evaluation devices: PNOZmulti PSEN ix1 PSENmag brown white blue black Legend Input OSSD Input OSSD T1, T2 Test pulse outputs PNOZ s3 PSEN ix1 PSENmag brown white blue black Operating Manual PSEN ma1.1p-12...
Prevent the safety switch and actuator being exposed to heavy shock or vibration. Make sure that the safety switch and actuator cannot be used as an end stop. Circumvention of the safety switch in a reasonably foreseeable manner must be preven- ted. Operating Manual PSEN ma1.1p-12 | 14 22190-EN-04...
Technical details [ 16]) can only be achieved by using the Pilz connection leads available as an accessory. If possible, do not install the safety switch and actuator on to ferromagnetic material. Changes to the operating distances are to be expected. In this case, use the spacer (see Order reference [ 19]).
Reaction time (actuator removed) 2 ms Environmental data Ambient temperature Temperature range -25 - 70 °C Climatic suitability In accordance with the standard IEC 60068-2-30 Humidity 93 % r. h. at 40 °C Operating Manual PSEN ma1.1p-12 | 16 22190-EN-04...
Page 17
1 Nm Dimensions Height 42,8 mm Width 26 mm Depth 13 mm Actuator dimensions Height 36 mm Width 26 mm Depth 13 mm Weight of safety switch 20 g Weight of actuator 20 g Operating Manual PSEN ma1.1p-12 | 17 22190-EN-04...
European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Authorised representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ostfildern, Germany Operating Manual PSEN ma1.1p-12...