Teaching In The Actuator; Psen Sl2-Il1-P; Psen Sl2-Il2-P; Psen Sl2-Il3-P - Pilz PSEN sl2-IL1-P Operating Manual

Table of Contents

Advertisement

Teaching in the actuator

7
Teaching in the actuator
7.1

PSEN sl2-IL1-P

Any corresponding Pilz actuator (see
is brought into the response range.
7.2

PSEN sl2-IL2-P

Teaching in the actuator for the first time:
The first actuator to be detected by the safety switch (see
taught in automatically as soon as it is brought into the response range.
To teach in a new actuator:
}
A maximum of 8 learning procedures are possible.
1. The actuator that is to be taught in must be brought into the safety switch's response
range as the only transponder. As soon as the actuator is detected, the "Safety Gate"
LED will flash yellow.
2. After a waiting period of 20 s, the "Safety Gate" LED has quick yellow flashes. Trigger a
system reset in the next 120 s by interrupting the supply voltage.
3. When the supply voltage is switched back on, the learning procedure is complete and
the number of permitted additional learning procedures is reduced by 1.
7.3

PSEN sl2-IL3-P

The first actuator to be detected by the safety switch (see
taught in automatically as soon as it is brought into the response range.
Operating Manual PSEN sl2-IL1/2/3-P
1005909-EN-02
NOTICE
– The actuator must not be removed during the learning procedure.
– It is no loner possible to reteach his actuator on the same safety
switch.
NOTICE
No other actuator may be taught in once this actuator has been taught.
Technical Details [
52]) is detected as soon as it
Technical details [
Technical details [
52]) is
52]) is
| 33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psen sl2-il2-pPsen sl2-il3-p

Table of Contents