Pairing With Wireless Trv Radiator Head - Salus SQ610 Quantum Full User Manual

Hide thumbs Also See for SQ610 Quantum:
Table of Contents

Advertisement

7.3 Pairing with Wireless TRV radiator head

PLEASE NOTE!
For easier installation, please make sure you have already added wireless TRV radiator heads to your ZigBee network (please refer to the wireless TRV
radiator head manual instruction).
1
Select "YES" by „
buttons. Confirm by
4
Select system type "RADIATORS"
using
or
confirm it by
button.
7
On the LCD you will see the number of paired TRV' s .
Once all TRV' s are paired - press
the pairing process.
2
" or „
"
button.
5
Hold antenna button for 10 sec. on all TRV' s
which you want to pair with your
buttons and
thermostat.
8
button to finish
Now thermostat is looking for the
signal from the coordinator...
When thermostat is succesfully
paired main screen will be
displayed.
3
5 sec.
OR
5 sec.
Open the ZigBee network
6
10 sec
You can pair up to 6 TRV' s with 1 thermostat.
All TRV' s have to be within the same room
with thermostat.
9
5 sec.
OR
5 sec.
Close the ZigBee network
3
3
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents