11. Factory Reset

To RESET SQ610 thermostat to it's factory default settings please follow steps below:
1
Press
button to enter the
main menu.
4
Select YES and confirm choice by
pressing

12. Error codes (error codes description with possible solutions)

ERROR
DISPLAY
CODE
DESCRIPTION
1.
TRV
TRV paired with thermostat - TRV
hardware error.
HARDWARE
PROBLEM
2.
FLOOR
Floor is overheated (heating mode).
/ Floor is overcooled (in cooling
SENSOR
mode).
OVERHEATED/
OVERCOOLED
3.
FLOOR
Floor sensor is broken.
SENSOR
DEFECT
4.
FLOOR
Floor sensor is shorted.
SENSOR
DEFECT
5.
CONNECTIVITY
Thermostat lost contact with the
CO10RF network coordinator or the
LOST COORD.
UGE600 internet gateway.
6.
CONNECTIVITY
Thermostat lost connection with the
wiring centre.
LOST WC
2
Go to the Admin Settings.
5
Wait few moments to finish factory
button.
ERROR DESCRIPTION
reset procedure.
• Reinstall the TRV head or replace it. If necessary, contact with the
SALUS Technical Department.
• Set the heating medium temperature or change floor sensor MAX/
MIN temperature setpoint in the „S1/S2 input" admin setting parame-
ter.
• Set the cooling medium temperature or change floor sensor MAX/
MIN temperature setpoint in the „S1/S2 input" admin setting
parameter.
• If floor sensor is connected to „S1/S2 input", check the wiring.
• If floor sensor is not connected, check the „S1/S2 input" parameters
settings.
• If floor sensor is connected to „S1/S2 input", check the wiring.
• If floor sensor is not connected, check the „S1/S2 input" parameters
settings.
• Check floor sensor wire insulation for any damages. Sensor resistance for
25°C=10kΩ.
• Check the coordinator/gateway power supply connection.
• Force identification process from the coordinator/gateway or thermostat.
Is the wiring centre turned ON and Status Network LED diode solid?
• If yes, send the heating signal from thermostat to the wiring centre
(change setpoint temperature).
3
Choose „Factory Reset" option.
TROUBLESHOOTING
69