Salus SQ610 Quantum Full User Manual page 70

Hide thumbs Also See for SQ610 Quantum:
Table of Contents

Advertisement

ERROR
DISPLAY
CODE
DESCRIPTION
7.
CONNECTIVITY
LOST TRV
8.
CONNECTIVITY
LOST RX 1
9.
CONNECTIVITY
LOST RX 2
10-17.
CONNECTIVITY
LOST ZONE 1-8
18.
WC / CB LOST
CONNECTIVITY
19.
WC / CB LOST
LINK-RX10RF
70
ERROR DESCRIPTION
Thermostat lost contact with the TRV
head.
Thermostat has lost connection with
the RX10RF receiver (RX1 mode).
Thermostat has lost connection with
the RX10RF receiver (RX2 mode).
Wiring centre has lost connection
with thermostat of the given zone:
e.g. 11 = with zone 1; 12 = with the
zone 2 etc. Error is displayed on all
thermostats.
Wiring centre has lost connection
with the CO10RF coordinator/UGE600
internet gateway.
Error is displayed on all thermostats.
Wiring centre has lost connection
with the RX10RF receiver operating in
RX1 mode.
Error is displayed on all thermostats.
• If LED diode of the Network Status is flashing, pair the wiring centre with
the system in accordance to the manual instruction and pair thermostat
with wiring centre.
• Check TRV head batteries.
• Send the heating signal from thermostat and check if the TRV
head is working.
• If the LED diode on the TRV head is flashing, repeat the pairing
procedure with thermostat according to the manual instructions.
• Is the RX10RF receiver plugged to the power supply and the top
LED diode is red? The Auto/Manual switch has to be set to AUTO
position.
• Force identification process from the coordinator/gateway side
and check if the devices are within the network.
• Send the heating signal from thermostat
• If the top LED diode is flashing, perform the pairing procedure
according to the RX10RF manual instruction.
• Is the RX10RF receiver plugged to the power supply and the top
LED diode is red? The Auto/Manual switch has to be set to AUTO
position.
• Force identification process from the coordinator/gateway side
and check if the devices are within the network.
• Send the heating signal from thermostat
• If the top LED diode is flashing, perform the pairing procedure
according to the RX10RF manual instruction.
• Check the thermostat power supply.
• Send the heating signal from thermostat.
• If necessary, reinstall the thermostat.
• Is the wiring centre turned ON and Status Network LED diode
solid?
• Force identification process from the coordinator/gateway side
and check if wiring centre is within the network.
• If LED diode of the Network Status is flashing, pair the wiring
centre with the system in accordance to the manual instruction and
pair all thermostats with wiring centre.
• Is the wiring centre turned on? Status Network LED diode should
be solid.
• Force identification process from the coordinator/gateway side
and check if devices are within the network.
• If the LED diode of the AUTO/MANUAL receiver switch is flashing,
follow the RX10RF manual instruction for pairing.
TROUBLESHOOTING