Parameter name
PIN CODE
DEVICE INFORMATION
CONNECT WITH GATEWAY
68
Parameter Values
- LEVEL 1 - Heating will be ON for 11min (3min to open the actuator, then
actuator will remain open for 5min, then closing the actuator will take
another 3min). The option is for small rooms with short loops, which can be
heated up quickly.
- LEVEL 2 - Heating will be ON for 15min (3min to open the actuator, then
actuator will remain open for 9min, then closing the actuator will take
another 3min). The option is for medium rooms with loops of medium
length.
- LEVEL 3 - Heating will be ON for 19min (3min to open the actuator, then
actuator will remain open for 13min, then closing the actuator will take
another 3min). The option is for big rooms, with long loops.
DISABLE
There are two variants that can be set for the PIN CODE feature:
ENABLE
- PIN CODE will be used only to lock admin settings menu,
- PIN CODE will be used to completely lock thermostat.
PIN CODE can be set from the Smart Home application or from device side.
In case of any problems with thermostat unlocking, please contact the
SALUS-Controls Technical Department.
PAIRED WITH
This function helps user to find out below informations about thermostat:
RF RANGE
PAIRED WITH - here we can check which devices are controlled by
BATTERY LEVEL
thermostat
IDENTIFY MODE
RF RANGE - this screen displays the value of RSSI (Received Signal Strength
SOFT
Indicator) between thermostat and coordinator (UGE600 or CO10RF) every
DEL OFFLINE DEVICE
3 seconds. If the wireless connection is lost, „LOST LINK" information is
displayed.
BATTERY LEVEL - information about percentage battery level status
IDENTIFY DEVICES - press
device side - you can check which devices are paired with thermostat (e.g.
wiring centre, TRV head etc.). During identification time of 10 minutes are
counted down. Press again
SOFT - information about thermostat firmware version
DELETE OFFLINE DEVICE - this function is available only when thermostat
is paired with CO10RF coordinator (in OFFLINE mode). It allows user to
remove OFFLINE devices which are still present in the CO10RF memory. In
a properly working network all devices should communicate. If there is any
device installed in the network and it is turned off from the power supply or
out of range (so it is not communicating with the network) it can be deleted
from thermostat side.
EXAMPLE:
Choose the offline device type you wish to delete:
CONTROL BOX, THERMOSTAT, RADIATORS, RX10RF RX1, RX10RF RX2.
After confirming the selection (e.g THERMOSTAT), use the „up" and „down"
keys and the following informations will be displayed:
- number of all devices in the network (e.g. THERMOSTAT 08 ALL)
- number of devices which are communicating with coordinator, (e.g.
THERMOSTAT 06 ONLINE)
- number of devices which are disconnected from power supply or out of
range (e.g. THERMOSTAT 02 OFFLINE).
At this point, pressing
YES
If you have configured the thermostat as a standalone device and now you
NO
want to add it to the gateway (pair with the other devices) you can use that
option
Description
button to enable identification process from
button to end identification process earlier.
button confirms offline devices removal.
Default
Values
DISABLE
YES

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents