RT510+ / RT510TX+ / RT510RF+ is a programmable room thermostat used to control room temperature. Device launching heating system by shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Extended features allows us to use various operating modes - automatic (time schedules), manual, frost protection or holiday. Before use please read this manual carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the cover. Do not use rechargeable batteries.
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is available on www.salus-controls.com/uk
868.0-868.6MHz; <13dBm
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU regulations.
RT510+ Thermostat | RT510TX+ Thermostat | |
Thermostat supply | 2 x AA alkaline batteries | 2 x AA alkaline batteries |
Thermostat rating max | 3 (1) A | - |
Outputs | Voltage free NO / COM / NC terminals | - |
Temperature range | 5 - 35°C | 5 - 35°C |
Temperature accuracy | 0.1°C or 0.5°C | 0.1°C or 0.5°C |
Control algorithm | ITLC / SPAN | ITLC / SPAN |
Radio frequency | - | 868 MHz |
Dimension [mm] | 120x96x27 | 120x96x27 |
RXRT510 Receiver | ||
Receiver supply | 230 V AC | |
Receiver rating max | 16 (5) A | |
Outputs | Voltage free NO / COM terminals | |
Radio frequency | 868 MHz | |
Dimension [mm] | 96x96x27 |
Terminal | Description |
1 - COM | Common Terminal |
2 - NC | Switched Live OFF |
3 - NO | Switched Live ON |
The DIP Switches can be found on the rear of your thermostat.
Control feature | ITLC | SPAN |
Operation | ITLC Internal Temperature Load Compensation for improved efficiency. | When Span is selected on DIP switch № 2, the DIP switch № 1 is not functional. |
Terminal | Description |
NO | Switch Terminal |
COM | Common Switch Terminal |
L, N | Supply (230 V AC) |
The DIP Switches can be found on the rear of your thermostat.
For all plug-in boiler receiver applications ensure SW1 is set to RAD.
Control feature | ITLC | SPAN |
Operation | When ITLC is selected on DIP switch № 2, the DIP switch № 1 is functional. You can choose between radiator or electric heater. | When Span is selected on DIP switch № 2, the DIP switch № 1 is not functional. |
In this mode, user can set the schedules for thermostat (temperature setpoints for specific periods of time). To do this, firstly choose programming mode: "5-2" (business days + weekend) or "24h" (each day separately) using parameter d04 from Installer mode. Programmed schedules should use all time periods.
This function is available only in automatic mode (schedule). If a new setpoint temperature will be set during the schedule - it will be maintained until next time interval starts according to programmed schedule.
Temporary Override mode will be disabled when new schedule will be set. TEST / PAIRIN
In this mode thermostat does not work according to the programmed schedule but it will maintain selected temperature.
To turn off the Manual Mode press
button. Once the manual mode is off, the hand icon
on the thermostat will disappear.
This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature for a specified number of hours (up to 9 hours). Once that time is over, thermostat returns to previous mode.
Turning off hourly temperature override mode before time's up
Temperature of the Frost Protection mode is set as default at 5°C. This temperature can be changed in Installer Mode in d03 parameter.
Turning Off the Frost Protection Mode
When the sleep mode is activated, all thermostat functions are paused.
In this mode the "frost protection" temperature is maintained for a specific number of days.
To turn off the Holiday Mode, hold down
button for 3 seconds. The airplane icon
should disappear from the display.
Note: If you are using the RT510RF+ pack, the pairing between the thermostat and the receiver is already done.
If you bought the RT510TX+ and RXRT510+ separately or if you want to re-pair thermostat with the receiver, make sure that the device is disconnected from the power supply and the switches on the receiver have been set to AUTO and ON. Then connect the receiver to the power supply and wait for the red LED to light steadily. Then switch to the OFF position and again to ON position quickly. The red flashing LED will confirm entering the pairing mode.
Begin the pairing process
End the pairing process
Once devices are successfully paired, LED on the receiver will go solid red. Press and hold TEST / PAIRING button for 3 seconds to end the pairing process.
Test the pairing process
Press TEST / PAIRING button to check the connection with the receiver.
Press TEST / PAIRING button again to return to the main screen.
dxx | Function | Parameter | Default value |
d01 | Temperature display increments | 0.1°C or 0.5°C | 0.5°C |
d02 | Temperature offset | +/- 3.0°C | 0.0°C |
d03 | Frost Protection setpoint temperature | 5.0°C - 17.0°C | 5.0°C |
d04 | Programmer selection | 5/2 or 24 hr (7d) | 5 |
Press the RESET button once. You can use a paper clip. Your thermostat will be reset and will start up automatically.
Remove the batteries without pressing any button.
Wait 2 minutes and insert the batteries again. Your device will be restarted.
When you want to change the batteries your device will use the internal memory to backup your settings. You have 30 seconds to change the batteries before losing your settings.
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth, Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961 E: sales@salus-tech.com
E: techsupport@salus-tech.com
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Salus Controls RT510+, RT510TX+, RT510RF+ Thermostat Quick Guide
Advertisement
Need help?
Do you have a question about the RT510+ and is the answer not in the manual?
Questions and answers