Provisioning 2 x 10G MDA and 4 x T1/E1 CES MDA on 7210 SAS-M
For 7210 SAS-M devices currently deployed or new deployments, to insert 2*10 MDA perform
the following steps:
1. Configure the BOF parameter "use-expansion-card-type" to m2-xfp. This provisions the
2. Configure the BOF parameter "no-service-ports", if using a 7210 SAS-M 24F 2XFP and
3. Re-boot the device.
4. The above steps are required for first-time use of 2 x 10G MDA or when changing the
In 7210 devices using 2 x 10G MDA, to insert CES MDA perform the following steps:
1. Configure the BOF parameter "use-expansion-card-type" to m4-ds1-ces. This will
2. Configure the BOF parameter "no-service-ports" to default, if using a 7210 SAS-M 24F
3. Re-boot the device.
4. The above steps are required when changing the MDA type in use. It is not needed, if a
NOTE: Insertion and removal of the CES MDA at any point of time into the system is supported,
if the BOF parameter configuration is set to default.
MDA port on 7210 SAS-Mxp:
The following are the ports in 7210 SAS-Mxp:
•
•
•
7210 SAS M, T, X, R6, R12, Mxp Interface Configuration Guide
Change of value assigned to 'use-expansion-card-type' BOF parameter, requires a reboot
so that a different MDA type can be used.
system to expect a 2 x 10G MDA for use in the expansion slot.
7210 SAS-M 24F 2XFP ETR variants.
MDA type in use. It is not needed, if a MDA is being replaced with a MDA of the same
type.
provision the system to expect a 4 x T1/E1 CES MDA for use in the expansion slot.
2XFP and 7210 SAS-M 24F 2XFP ETR variants.
MDA is being replaced with a MDA of the same type.
4 x 10G SFP+
22 x 1G SFP
2 x Combo (SFP or Copper)
Interface Configuration
Page 15