Table 17: Internal Port Resources On Different Imms - Alcatel-Lucent 7210 SAS M Interface Configuration Manual

Service access switch
Hide thumbs Also See for 7210 SAS M:
Table of Contents

Advertisement

resources of loopback port. Please see Table 17 on page 151 below to know the number of internal vir-
tual port resources that are available on different flavors of IMMs. It can also be obtained using the
command show system internal-loopback-ports detail. User might need to configure resources of a
front-panel port for use with OAM tools that needs the loopback port resources, if all the internal port
resources are used up. In other words, if user intends to use all the OAM tools simultaneously, then
additional front-panel ports need to be configured for use with some of the OAM tools. The port config-
ured for use by one OAM tool cannot be shared with other OAM tools. In other words, each OAM tool
requires dedicated resources for its use.
NOTE: When configuring internal port resources or front-panel port resources for testhead OAM tool
and mac-swap OAM tool, the port needs to be on the same IMM as the test SAP. It cannot be on a dif-
ferent IMM.
• On 7210 SAS-Mxp, user can use the one available internal port (that is, port 1/1/29) for use with either
mac-swap or mirroring or testhead OAM tool. If user intends to use all the OAM tools simultaneously,
then additional front-panel ports need to be configured for use with one of the tools.
• The following table indicated the Internal port resources on different IMMs available:

Table 17: Internal port resources on different IMMs.

IMM 2 x 10G XFP (imm-
sas-2xfp)
IMM 10 x 1G SFP (imm-
sas-10sfp)
IMM 10 x 1G SFP + 1 x
10G XFP (imm-sas-
10sfp+1xfp)
IMM 4 x 10G SFP+
(imm-sas-b-4sfp+)
IMM 2 x 10G SFP+
(imm-sas-b-2sfp+)
IMM 10 x 1G SFP + 1 x
10G SFP+ (imm-sas-b-
10sfp-1sfp+)
IMM 11 x 1G CSFP or 22
x 1G SFP (imm-sas-b-
11csfp)
IMM 16 x 10/100/1000
Base-T (imm-sas-b-16tx)
Default
None
Parameters
port-id — Specifies the physical port ID in the slot/mda/port format.
mac-swap — Specifies the port specified by the port-id is dedicated for use by the port loopback with mac-
swap application/OAM tool.
7210 SAS M, T, X, R6, R12, Mxp Interface Configuration Guide
Internal Port
Resources
IMMs
2 x 1GE ports
2 x 1GE ports
2 x 1GE ports
1 x 1GE ports
2 x 1GE ports
2 x 1GE ports
1 x 1GE ports
1 x 1GE port
Interface Configuration
Page 151

Advertisement

Table of Contents
loading

This manual is also suitable for:

7210 sas t7210 sas x7210 sas r67210 sas mxp os7210 sas r12

Table of Contents