Alcatel-Lucent 7210 SAS M Interface Configuration Manual page 192

Service access switch
Hide thumbs Also See for 7210 SAS M:
Table of Contents

Advertisement

Note: See the 7210 SAS-M Services guide for more information on CESoPSN services.
Default
all-ones
Parameters
all-ones — Defines the 8 bit value to be transmitted as 11111111.
pattern — Transmits a user-defined pattern.
Values
idle-signal-fill
Syntax
idle-signal-fill {all-ones | pattern pattern}
no idle-signal-fill
Context
config>port>tdm>ds1>channel-group
config>port>tdm>e1>channel-group
Description
This command defines the signaling pattern to be transmitted (4-bit value) when the circuit emulation
service is not operational or temporarily experiences underrun conditions. This command is only valid for
CES with CAS.
Note: See the 7210 SAS-M Services guide for more information on CESoPSN
Default
all-ones
Parameters
all-ones — Defines the 4 bit value to be transmitted as 1111.
pattern — Transmits a user-defined pattern.
Values
loopback
Syntax
loopback {line | internal | fdl-ansi | fdl-bellcore | payload-ansi}
no loopback
Context
config>port>tdm>ds1
config>port>tdm>e1
Note: Only line and internal options are supported for "e1".
Description
This command puts the specified port or channel into a loopback mode. A line loopback, loops frames
received on the corresponding port or channel back towards the transmit (egress) direction before reaching
the framer. The bit stream is not reframed. The electrical signal is regenerated by the Tx line interface unit
(LIU) and the timing is provided by the Rx LIU.
An internal loopback, loops the frames from the local router back to the framer. This is usually referred to as
an equipment loopback. The Tx signal is looped back and received by the interface.
Note: The loopback command is not saved to the system configuration.
The no form of this command disables the specified type of loopback.
7210 SAS M, T, X, R6, R12, Mxp Interface Configuration Guide
0 to 255 (can be entered in decimal, binary, or hexadecimal format)
0 to 15 (can be entered in decimal, binary, or hexadecimal format).