10.4 Home and Near Home Input Logic

10.4.1 When to Specify NO Contact

In cases like that below where power is supplied to the input circuit of the unit, select "NO
contact" for the parameter home input logic or the near home logic.

When to specify NO contact

1. If the input switch contact is the NO contact.
2. If the input sensor goes ON when the home or near home position is detected.
3. When the Z phase of the driver is connected.
Current flows when the home or near home position is detected.

10.4.2 When to specify NC contact

In cases like that below where power is supplied to the input circuit of the unit, select "NC
contact" for the parameter home input logic or the near home logic.

When to specify NC contact

1. If the input switch contact is the NC contact.
2. If the input sensor goes OFF when the home or near home position is detected.
WUME-GM1PG-01

10.4 Home and Near Home Input Logic

10-11