Operation At Over Limit Input - Panasonic GM1 Series Reference Manual

Motion controller
Hide thumbs Also See for GM1 Series:
Table of Contents

Advertisement

8.2 Operation at Over Limit Input

8.2 Operation at Over Limit Input

Operation at over limit input
Operations depend on the status of over limit input (+) and over limit input (-) as follows.
Condition
When JOG operation is
started
During JOG operation
Input valid logic of over limit input
● When the over limit switches (+) (-) are not connected to the pulse output unit, change the
over limit input logic of the Pulse_4Axes parameter to "NO contact". The default is "NC
contact", and an over limit error occurs.
Precautions on Over limit switch
● An over limit input valid for JOG operation, home return and pulser operation is the one
logically found in the direction of the movement. Even if an over limit switch (-) is input for a
movement in (+) direction or an over limit switch (+) is input for a movement in (-) direction,
the operation will not stop.
● Make sure that an over limit switch (+) is set in the direction of the elapsed value increment
and an over limit switch (-) in the direction of the elapsed value decrement.
● When a switch is not set in the correct direction, the followings might be a cause. Check your
settings and correct them.
1) An over limit switch, (+) or (-), is not set in a correct direction.
2) CW / CCW output method is set reverse for the connection of the pulse output unit and
the motor driver.
3) A sign input logic is set reverse for the connection of the pulse output unit and the motor
driver.
4) Among the Pulse_4Axes parameters, the rotation direction (forward or reverse) of pulse
output is reversely specified.
8-6
Direction
Forward
Reverse
Forward
Reverse
Limit status
Over limit input (+): ON
Over limit input (-): ON
Over limit input (+): ON
Over limit input (-): ON
Over limit input (+): ON
Over limit input (-): ON
Operation
Not executable, Error
occurs.
Executable
Executable
Not executable, Error
occurs.
Stop, Error occurs.
Stop, Error occurs.
WUME-GM1PG-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Agm1pg04tAgm1pg04l