Determining the Mounting
Position and Installing
Leveling Sensors
front of
trailer
section A
front
left jack
roadside
rear
left jack
section B
rear of
trailer
Fig.18
lci1.com
tongue jack
right jack
curbside
right jack
574-537-8900
Ground Control
Leveling OneControl
Touch Panel
Installation and Owner's Manual
(For Aftermarket Applications)
Installing Leveling Sensors
The leveling sensors have a limited mounting area for
proper performance. The front sensor must be within
power
36" from the front of the frame as signified by section A
in (Fig.18). Make sure the front sensor is mounted in line or
in front of the front leveling jacks. The rear sensor must be
in line with or behind the rear leveling jacks, as signified
by section B in (Fig.18). Both the front sensor and the rear
sensor must also be mounted in line with the center of the
frame, as signified by the dotted blue line in (Fig.18).
The Leveling Sensors (Fig.19) must be oriented on the
crossmembers with the arrows on the top of the sensor
pointing in the correct direction (Fig.19). See (Fig.18),
sections A and B, for location clarification.
front
Fig.19
NOTE: The following process will be repeated for both
sensor installations.
NOTE: If the frame is Ground Control Travel Trailer ready,
it may be possible that the Leveling Sensor Mounting Plate
may have already been pre-installed onto the frame.
rear