Using LANVIEW
Table 4-1 LANVIEW LEDs (Continued)
LED
Color
Amber
and off
RX
None
(Receive)
Green
Amber
RX
Red
TX
None
(Transmit)
Green
Red
4-4
Troubleshooting
State
Alternating (67% on,
33% off). Indicates that a
shutdown process has
completed. This
indication will remain for
60 seconds before
automatically restarting.
No link. No activity. Port
enabled or disabled.
Solid. Link present, port
enabled, no traffic is
being received by the
interface.
Flashing. Link present,
port enabled, traffic is
being received by the
interface.
Blinking. Indicates
collisions. This
indication is only
supported on 10/100
ports.
Port enabled, but no
activity.
Flashing. Indicates data
transmission activity.
Rate of flashing indicates
the data rate.
Flashing. Fault or Error
(collision).
Recommended Action
While in this state, you have 60 seconds to
safely remove the DFE module from the
chassis.
None.
None.
None.
Contact Enterasys Networks for technical
support.
If it is known that the port should be active
and is not, contact Enterasys Networks for
technical support.
None.
None, unless there is a high rate of activity.
In this case, check for network
configuration problems or a defective
device.