6.7
Replacing the neon lamp
Before starting any operation on the machine
make sure that the power supply of the distributor
is off.
Access to the upper neon lamp
- Lift the bracket and remove the cup column (Fig.6.23)
- Unscrew the two external screws and loosen the two nuts as
shown in Fig 6.24
- Remove the protection casing and replace the neon lamp by
carefully taking it out of its support (Fig.6.24).
- After replacing the lamp make sure that it works.
- After cutting off again the power supply of the machine, as-
semble the parts in the reverse order.
Access to the lower neon lamp
- Unscrew the two external screws and loosen the two nuts as
shown in in Fig 6.24
- Remove the protection casing and replace the neon lamp by
carefully taking it out of its support (Fig.6.24).
- After replacing the lamp make sure that it works.
- After cutting off again the power supply of the machine, as-
semble the parts in the reverse order.
Fig. 6.24
Fig. 6.23
13W
6W
66