BIANCHI VENDING BVM972 Use And Maintenance Manual page 50

Table of Contents

Advertisement

5.3.14.1 'System Audit'
Aut. Tub.
Value of coins automatically inserted
[00000÷99999]
Man. Tub.
Value of coins manually inserted
[00000÷99999]
Aut. Em.
Value of coins automatically depleted
[00000÷99999]
Man. Em.
Value of coins manually depleted
[00000÷99999]
Acc. CP.
Value of coins loaded on key
[00000÷99999]
Add. CP.
Value of coins unloaded through key
[00000÷99999]
Reset Tubes
Code
Enter code [0000÷9999, default 0001]
Replace code?
Replace code? [Yes/No]
Code
Code setting [0000÷9999]
Set to zero?
Set tube data? [Yes/No]
5.3.15 'Clock' Menu
The following menus are available:
Hour/minute
Date
Switch on
Cleanings
Disinfection
5.3.15.1 'Hour/minute'
Set hour/minute
Sets current hour and minute
[00:00÷23:59]
5.3.15.2 'Date'
Set Date
Sets current date [Mo dd/mm/yy]
5.3.15.3 'Switch on'
Start 1
Sets switch on time 1 [00:00÷23:59]
Stop 1
Sets switch off time 1 [00:00÷23:59]
D.A. Off 1?
Decide to switch off the whole distributor or
to leave in St-by the coin box only[On/Off].
Linked to time section 1
Start 2
Sets switch on time 2 [00:00÷23:59]
Stop 2
Sets switch off time 2 [00:00÷23:59]
D.A. Off 2?
Decide to switch off the whole distributor or
to leave in St-by the coin box only [On/Off].
Linked to time section 2
If 'Start? is higher than or equal to 'Stop' the switch on time section
is not enabled. If this is made on both time sections, the machine
will be always on. If a distributor is in off condition, the display will
show in line 1 the word Off and in line 2 the real time.
St-By Boiler?
Activates the boiler during the st-by hours
programmed in the clock menu [On/Off] If
On the boiler will keep the st-by temperature
according to the following algorithm, If Off
the boiler will remain off
Temp Boiler X
Sets the temperature of all boilers during
st-by period. According to the number of
boilers included in the battery, the X fi eld
will be updated.
5.3.15.4 'Cleanings'
Cleaning 1
Sets time of cleaning 1 [00:00÷23:59]
Cleaning 2
Sets time of cleaning 2 [00:00÷23:59]
Cleaning 3
Sets time of cleaning 3 [00:00÷23:59]
Cleaning 4
Sets time of cleaning 4 [00:00÷23:59]
These sections can be set and displayed for the hot machine
only
5.3.15.5 'Disinfection'
T disinfection
T disinfection [0÷120s]
Disinfection delay
Disinfection delay [0÷240s]
5.3.16 'Distributor Test' Menu (with Password)
Machine cycles allowing the operator to check the proper operation
of the peripherals. With this password all components confi gured
in the setting fi le will be tested. This password can be modifi ed
by Bianchi Vending Group only.
The line operator must load only the setting fi le and enter this
pwd. The machine will warn the operator to make sure that no
product is contained in the distributor. Only after confi rming with
enter key, the distributor will perform the machine test.
For testing procedure please refer to SS005-04 specifi cations.
By entering password 88000, enabled only if a Vega power is
connected, the motor test can be performed. When the pwd is
entered the display will show:
Set motors BVM600 X
X specifi es the number of BVM600 machine which will have the
motor alignment.
5.3.17 Default data
Code
Enter code [6666]. It will be a fi xed code for
all established by Bianchi.
Reset?
Reset factory data? [Yes/No]
When the distributor is programmed in the assembly line, the std
settings are duplicated and inserted in the default data table. If the
confi guration is reset, the same data as loaded in Bianchi Vending
Group spa will be obtained.
5.3.18 'Remote Connection' Menu
5.3.18.1 Bianchi Telemetry
In order to avoid to use third party services (Digisoft, Alcatel,
Modules, etc.) which are expensive and mainly designed for major
distributions, Bianchi System can be used.
The possibilities are several and depend on the target interaction
level with distributors.
To get only the sales data it is suffi cient to have an e-mail box to
receive the EVA data in text format. Data interpretation will be at
customer's charge. The sending of the data is time only, program-
med in the board and only if the clock chip is installed.
For a more complete management a computer at the customer's
premises must be equipped with a GSM modem and a windows
management program.
50
Set motors BVM600 to zero [On/Off]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvm952

Table of Contents