AUTOMATIC VENDING
INSTALLATION AND MAINTENANCE MANUAL
ATTENTION: Important safety indications
READ the instruction manual machine carefully before using the machine
.or any service or maintenance switch off the machine
ATTENTION: machine switched on
ATTENTION: hot parts in contact!
BE.ORE USING THE MACHINE, READ THIS MANUAL CARE.ULLY .OR ITS CORRECT USE IN
ACCORDANCE WITH THE CURRENT SA.ETY STANDARDS.
The user is defined as the person authorized to collect drinks from the automatic distributor.
The user is not allowed to undertake any maintenance operations either ordinary or extraordinary.
In the event of a fault the user is obliged to notify the maintenance technician or the person responsible
for running the automatic distributor.
The maintenance technician is defined as being the person responsible for filling up the containers with
soluble products, sugar, coffee, stirrers and cups.
The maintenance technician is also responsible for cleaning the distributor (see operations indicated in
chapter 9.0). In the event of a fault the maintenance technician must call the installation technician.
The installation technician is defined as the person responsible for the installation of the automatic distributor,
the starting up operations and the function settings.
Each regulation operation is the exclusive responsibility of the installation technician who also holds the
programming access password.
Antares
ANTARES
Cod. 11081821

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ANE23BL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BIANCHI VENDING ANE23BL

  • Page 1 ANTARES Antares AUTOMATIC VENDING INSTALLATION AND MAINTENANCE MANUAL Cod. 11081821 ATTENTION: Important safety indications READ the instruction manual machine carefully before using the machine .or any service or maintenance switch off the machine ATTENTION: machine switched on ATTENTION: hot parts in contact! BE.ORE USING THE MACHINE, READ THIS MANUAL CARE.ULLY .OR ITS CORRECT USE IN ACCORDANCE WITH THE CURRENT SA.ETY STANDARDS.
  • Page 2 ANTARES Keys at the disposal of the Key at the disposal of the MAINTENANCE and INSTALLATION INSTALLATION technician technicians This key can also be given to the maintenance technician exclusively authorized undertake operations as described in chapter 8.0 Tools necessary undertaking interventions on the automatic dispenser.
  • Page 3: Table Of Contents

    ANTARES INDEX Important notices The user must not under any circumstances remove the guards that require a tool for removal. 6.5.1 Regeneration of water softener resins 6.5.2 .illing of water circuit 6.5.3 Cleaning of parts in contact with food substances Knowledge of the information and instructions 6.5.4 Payment system installation...
  • Page 4 ANTARES All the operations necessary to maintain the machine’s efficiency, before and during it’s use are at the users charge. – Any manipulations or modifications made to the machine that are not previously authorized by the manufacturer, relieve the latter from any responsibility for damages deriving from, and will automatically result in the cancellation of the machine guarantee terms.
  • Page 5 ANTARES AVERAGE CONSUMPTIONS: WATER SUPPLY CUP DISPENSER BOILER RESISTANCES .ig. 2.1...
  • Page 6 ANTARES 3.1 Machine description (.ig.3.1) .oreseen use Models ANTARES E ANTARES I .ig. 3.1 The manual is compiled for the most complete model: it is therefore possible, to find descriptions or explanations not related to your machine. ANTARES ENS ANTARES INS...
  • Page 7 ANTARES Basic operation concepts CUP DISPENSING SUGAR DISPENSER .ig. 3.2 .ig. 3.3 .ig. 3.4...
  • Page 8 ANTARES SPOON DISPENSING INSTANT DRINKS .ig. 3.5 .ig. 3.6 .ig. 3.7 .ig. 3.9 .ig. 3.8...
  • Page 9 ANTARES ESPRESSO CO..EE .ig. 3.10 .ig. 3.11 .ig. 3.12 .ig. 3.13...
  • Page 10 ANTARES Moving and transport (.ig.4.1) Avoid : – lifting the distributor with ropes or presses – dragging the distributor – upset or lay down the distributor during transport – give jolts to the distributor – bumping it – overloading it with other packages –...
  • Page 11 ANTARES .ig. 4.5 The packing material must not be left accessible to others, as it is a potential environmental pollution sources. .or the disposal contact qualified companies authorized. .ig. 4.6 .ig. 4.7 .ig. 4.8...
  • Page 12 ANTARES SA.ETY NORMS INSTALLATION Positioning ATTENTION! (.ig.6.2). Always disconnect the POWER CABLE before maintenance or cleaning interventions. ABSOLUTELY DO NOT INTERVENE ON THE MACHINE AND DO NOT REMOVE ANY PROTECTION BE.ORE THE Nuova Bianchi declines all responsibility for inconveniences due COOLING O.
  • Page 13 ANTARES (.ig. 6.5) (.ig.6.6). Main Power supply connection .ig. 6.3 .ig. 6.4 We suggest to check that: .ig. 6.6 .ig. 6.5 Nuova Bianchi S.p.A. .ig. 6.7 The power supply cables are to be replaced by skilled personnel. .ig. 6.8...
  • Page 14 ANTARES Starting up of the unit The clamp of the power cable junction box remain under tension (.ig.6.10-pos.1) as well as the service switch inside the distributor. (.ig.6.11- pos.1). .ig. 6.9 The opening and the possible connection with the distributor’s door open must be performed only by authorized in carrying out these operations.
  • Page 15 ANTARES Installation 6.5.1 Water Softener Resin regeneration 6.5.2 .illing the water circuit .ig. 6.13 .ig. 6.14 .ig. 6.15 .ig. 6.16 .ig. 6.18 .ig. 6.17...
  • Page 16 ANTARES Before connecting the power supply, ensure that the distributor has been connected to the water mains and that the water tap has been turned on. .ig. 6.19 6.5.3 Cleaning of the parts in contact with food substances .ig. 6.20 .ig.
  • Page 17 ANTARES 6.5.4 Payment system installation (.ig. 6.24) (.ig. 6.25) .ig. 6.24 6.6 Product container loading (with machine off) 6.6.1 Loading containers (.ig.6.26) (.ig.6.27) .ig. 6.25 .ig. 6.26 .ig. 6.27...
  • Page 18: Label Application

    ANTARES 6.6.2 Product selection label application (Chapter “8.0 MAINTENANCE). .ig. 6.28 6.6.3 Cup loading .ig. 6.29 .ig. 6.30 .ig. 6.31...
  • Page 19: Spoon Loading

    ANTARES 6.6.4 Spoon loading 6.6.5 Insertion of waste grounds bag The ANTARES I models do not have the spoon dispensing column as the sugar is mixed directly with the products. .ig. 6.32 .ig. 6.33 .ig. 6.34 .ig. 6.35...
  • Page 20 ANTARES General description and preliminary operations 7.1.1 Language selection .unction description 7.2.1 TIME-DOSES 7.2.2 TIME SNACK 7.2.3 PRICES 7.2.4 DISCOUNTS 7.2.5 PRICE SELECTION General description and preliminary operations 7.2.6 INCLUDE SELECTIONS/JUGS PROGRAMMING KEY 7.2.7 MILK .IRST 7.2.8 OPTIONS 7.2.9 COINS 7.2.10 SALES 2.11 TEMPERATURE 7.2.12 EURO OPTIONS...
  • Page 21 ANTARES Programming panel Maintenance panel (espresso version) Maintenance panel (soluble version)
  • Page 22 ANTARES KEYBOARD PROGRAMMING Vega keyboard: MAINTENANCE (espresso version) (soluble version) Vega keyboard...
  • Page 23 ANTARES .ig. 7.2 * Soluble version only...
  • Page 24 ANTARES TIME-DOSES TIME SNACK (with Master/Slave) PRICES DISCOUNTS PRICE SELECTION INCLUDE SELECTIONS/JUGS MILK .IRST OPTIONS COINS SALES TEMPERATURE EURO OPTIONS MDB DATA MDB PIPE .ILLING MDB PIPE EMPTYING EXECUTIVE DATA CLOCK Note:...
  • Page 25 ANTARES 7.2 .unction description sugar time (soluble version) 7.2.1 TIME-DOSES (.ig. 7.4) grinder time-out (espresso version): pump timeout (espresso version): sugar delay (soluble version): coffee time (soluble version): NB.: in the espresso versions, the control of the water dose in the instant selections is done by means of a flow meter.
  • Page 26 ANTARES (with Master/Slave) (.ig.7.5) Note: .or access to the headings after “Trial”, password 88000 must be entered. .ig. 7.5...
  • Page 27 ANTARES 7.2.3 PRICES (.ig.7.6) .ig. 7.6...
  • Page 28 ANTARES 7.2.4 DISCOUNTS (.ig. 7.7) .ig. 7.7...
  • Page 29 ANTARES 7.2.5 PRICE SELECTION (.ig. 7.8) .ig. 7.8...
  • Page 30 ANTARES 7.2.6 INCLUDE -SELECTIONS/JUGS (.IG.7.9) .ig. 7.9...
  • Page 31 ANTARES 7.2.7 MILK .IRST (.ig. 7.10) .ig. 7.10...
  • Page 32 ANTARES 7.2.8 OPTIONS (.ig.11) Note: - The MDB coin box has priority over the other coin boxes, followed by Executive and then G13. - The “Credit timeout” parameter exclusively refers to the Vega card. - The “Perman credit” parameter only functions if “Multi-sales” is engaged.
  • Page 33 ANTARES * Soluble version only .ig. 7.11...
  • Page 34 ANTARES 7.2.9 COINS (.ig.7.12) .ig. 7.12...
  • Page 35 ANTARES 7.2.10 SALES (.ig.7.13) (N.B. active only for coins and G13) .ig. 7.13...
  • Page 36 ANTARES 7.2.11 TEMPERATURE (.ig.7.14) .ig. 7.14...
  • Page 37 ANTARES 7.2.12 EURO OPTIONS (.ig. 7.15) Nota: The “Visualiz. Point “parameter is only displayed if the currency/euro conversion is O..ig. 7.15...
  • Page 38 ANTARES 7.2.13 MDB DATA (.ig. 7.16) Note: the programming of the coin engagement function will only come into effect after switching the coin box off and then on again and/or the cards. .ig. 7.16...
  • Page 39 ANTARES 7.2.14 MDB PIPE .ILLING (.ig. 7.17) .ig. 7.17...
  • Page 40 ANTARES 7.2.15 MDB PIPE EMPTYING (.ig. 7.18) .ig. 7.18...
  • Page 41 ANTARES 7.2.16 EXECUTIVE DATA (.ig. 7.19) .ig. 7.19...
  • Page 42 ANTARES 7.2.17 CLOCK (.ig.7.20) Washing Discount Hour/minute set: Switch on: .ig. 7.20...
  • Page 43 ANTARES Maintenance panel (espresso version) IMPORTANT ! This operation is to be undertaken with the machine on, and therefore is only permitted to the technical staff authorized to carry out such operations. NOTE: so as to cancel a test pre-selection without dispensing drinks it is sufficient to press the service key inside the door again.
  • Page 44: Procedure For Distributor Cleaning

    ANTARES 9.1.3 Daily cleaning recommended Cleaning and Loading So as to guarantee the correct functioning of the distributor .or all cleaning operations follow the instructions indicated during time it is necessary to effect some operations in paragraph 9.1.1. periodically, some of which are indispensable for the observance of the health standard norms.
  • Page 45 ANTARES (.ig. 9.4) (.ig. 9.5) (.ig. 9.6) .ig.9.4 .ig.9.5 .ig.9.6 9.1.4 Weekly cleaning (.ig. 9.7). (.ig. 9.8) (.ig. 9.9) .ig.9.7 .ig. 9.8 .ig. 9.9...
  • Page 46: Ordinary And Extraordinary

    ANTARES 9.1.5 Product loading 9.2 MAINTENANCE EACH EVERY SIX EVERY 10.000 RECOMMENDED EVERY DAY EACH WEEK MONTH MONTHS 9.2.1 Ordinary and Extraordinary Maintenance .or all operations that require the disassembly of the distributors’ components, make sure that the latter is switched off. chapter 6.5.3.
  • Page 47 ANTARES 9.2.3 Nuova Bianchi Coffee group maintenance .ig. 9.10 .ig. 9.11 .ig. 9.12) .ig. 9.13 .ig. 9.10 .ig. 9.11 .ig. 9.12 .ig. 9.13...
  • Page 48: Dosage And Grinding Regulation

    ANTARES INDICE DI FASE 9.3 Regulations INDICE DI EROGAZIONE 9.3.1 Dosage and grinding regulations .ig. 9.14 - Ground coffee gram weighting (.ig.9.15) .ig. 9.15 9.3.2 Regulation of the instant solenoid water delivery valves Regulation of the degree of grinding fig.9.16 (.ig.
  • Page 49 ANTARES 9.4 Resin regeneration of the water softner ° french 60cc 130cc .ig. 9.18 (.ig. 9.18) (.ig. 9.19) .ig. 9.19 .ig. 9.20 (.ig. 9.20) 9.5 Neon light replacement (optional). Before undertaking any operations on the machine ensure that the distributor power supply is disconnected.
  • Page 50 ANTARES .ig.9.24 .ig. 9.24 9.6 Inactivity (.ig. 9.25) .ig. 9.25 (fig. 9.26) .ig. 9.26...
  • Page 51 ANTARES MASTER CARD ALARMS Is engaged in the event of an eprom error. On engaging the reset mes sage the missing Undertake alarm reset. default data will also be recharged on the eprom (only if this alarm is present). This alarm is only engaged if the Executive or Mdb c oi n box i s e nga ge d.
  • Page 52 ANTARES Occurs if on reset the set temperature of under °15 is not obtained in under 15 seconds, or if during Check the programming parameters. Check normal function the temperature remains under the clixon 60°c for 15 minutes. Memorized signals Undertake to fill the container Is engaged if the programmed grinder time out is engaged.The display shows the...
  • Page 53 ANTARES I s engaged when the value of the purifier Regenerate the purifier. Reset the decounter is equivalent to zero. programmed purifier decounter. I s engaged when the value of the grinder Replace the grinders.Reset the decounter is equivalent to zero. programmed grinder decounters.
  • Page 54 ANTARES α α α α α % % % % % Ω Ω Ω Ω Ω π π π π π...