5.4 MAINTENANCE

Direct selection keyboard –Espresso version
Maintenance is performed by pressing the key 'Service'.
In line 1 "Maintenance xxx" will be displayed , where xxx displays
the boiler temperature, and in line 2 the possible detected alar-
ms.
Pressing twice the key Service, the stand by heating phase will
be bypassed, allowing you to perform test selections even on non
regimen temperatures. Pressing a key the slave boiler temperature
will be displayed in scroll.
The maintenance panel has the following functions (which can be
enabled by WinBianchi):
In the maintenance mode the keys have the following
meaning:
01: Group rotation
02: MDB tube fi lling
03: MDB tube depletion
04: Input test and empty pipes for MDB
05: Reset
alarms
06: Complete test for one selection also Vega
07: Only water test
08: Nozzle movement
09: Column rotation
11: Alarm scrolling (if they are present)
12: Total entries display (cancellable) for 5 s
13: Cup release
14: Mixer test
15: Refi ll
16: Test without sugar
17: Spoon
Code keyboard
In maintenance mode it is necessary to enter in sequence,via the
alphanumeric keyboard, the numbers shown to obtain the desired
function.