7.2.9.3
Setting the relay output (Relay Output)
This function enables the control of ARPAALM terminal (on the terminal board
circuit).
Procedures
Open the Serviceman Menu.
1)
2)
Perform the following menu open procedure to open the Relay
Output menu.
3)
Left-click the
The Relay Output mode is switched.
Click the item button corresponding to the item to be changed.
4)
The item can be turned on / off.
7.2.9.4
Setting the ALR output (ALR Output)
This function enables the control of ALR port (See Section 7.2.1 "Communication
Port Setting (COM Port Setting)").
Procedures
Open the Serviceman Menu.
1)
>
JMA-7100 Instruction Manual
2. Installation Menu
6. Alarm System
2. Relay Output
1. Relay Output Mode
: The output is continuously controlled.
Continuous
: The output is intermittenly controlled.
Intermittent
: The relay output is turned on when alarm have issued.
On
: The relay output is not turned on when alarm have issued.
Off
: There is a dangerous target. (tracked target)
2. TT CPA/TCPA
: There is a dangerous target. (AIS target)
3. AIS CPA/TCPA
: A new target is acquired in the automatic acquisition zone.
4. New Target
: There is a lost target. (Target Tracking / AIS).
5. Lost
7- 23
7.SETTINGS FOR SYSTEM OPERATION
button in the menu.
>
7.2 SETTINGS
7