Honeywell NOTIFIER NFW-50X Manual page 64

Addressable fire alarm control panel
Hide thumbs Also See for NOTIFIER NFW-50X:
Table of Contents

Advertisement

Programming
1=STANDARD ADJECTIVE
2=STANDARD NOUN
3=CUSTOM ADJECTIVE
4=CUSTOM NOUN
Noun/Adjective Screen

1=NORTH
2=SOUTH
3=EAST
Adjective Screen #1

1=3RD
2=4TH
3=5TH
Adjective Screen #5
1=STANDARD ADJECTIVE
2=STANDARD NOUN
3=CUSTOM ADJECTIVE
4=CUSTOM NOUN
Noun/Adjective Screen

1=BASEMENT
2=BOILER RM
3=CLASSROOM
Noun Screen #1

1=KITCHEN
2=LOBBY
3=OFFICE
Noun Screen #5
Pressing 3 or 4 while viewing the Noun/Adjective Screen will display screens similar to the previous Adjective and Noun Screens. The
new screens will list Custom Adjectives and Nouns which have been programmed into the control panel using the FS-Tools program-
ming utility.
Description
EDIT CONTROL
1=ADJECTIVE/NOUN
2=DESCRIPTION
Edit Control Screen #4
A flashing cursor will appear at the first asterisk to the left. The programmer can enter additional descriptive information about the
device being programmed. This information will appear on the display along with the standard device label information.
A maximum of 20 characters (including spaces) can be entered. To enter alphanumeric characters from the keypad, repeatedly press the
appropriate key until the desired character is displayed in the first position. For example, to enter the letter B, press the 2 (ABC) key three
times to toggle through the characters 1, A, and B. Press the right arrow key to move the cursor one position to the right and repeat the
process to enter the next character. To enter a space, press the * (QZ) key four times until a blank appears in the desired position. When
all characters have been entered, press the Enter key to store the information. The display will return to the Edit Control Screen #4, dis-
playing the new information at the bottom of the screen.
Recall/Increment Function
In addition, the user may use the Recall/Increment function at any time when the cursor is on the first letter of the Adjective or Noun
field as follows:
If the zero key is pressed, a 0 is placed in the first letter position.
If the zero key is then pressed a second time with no intervening key actions, the entire Adjective field is replaced with the field
entered for the previous device programmed, and the cursor moves to the last character of the field (Recall function). The Recalled
Adjective or Noun field may now be changed letter-by-letter.
If the zero key is pressed again with no other intervening key actions and the last character in the field is a number 0-9, the number
is incremented by one. If the last character is a letter, it changes to a 0. If the last character is 9 it goes to 0.
64
Pressing 1 while viewing the Noun/Adjective Screen will cause the following screen(s) to be displayed.
Note that the keyboard down arrow key must be pressed to see all the Adjective screens. Press the number
corresponding to the adjective that is to be used as a descriptor for the location of the control module cur-
rently being programmed.

1=WEST
2=FRONT
3=CENTER
Adjective Screen #2

1=FLOOR 1
2=FLOOR 2
3=FLOOR 3
Adjective Screen #6
Pressing 2 while viewing the Noun/Adjective Screen will cause the following screen(s) to be displayed.
Note that the keyboard down arrow key must be pressed to see all the Noun screens. Press the number cor-
responding to the noun that is to be used as a descriptor for the location of the control module currently
being programmed.

1=CLOSET
2=CORRIDOR
3=ELECTRIC RM
Noun Screen #2

1=PATIENT
2=RESTROOM
3=ROOM
Noun Screen #6
The Description selection allows the programmer to enter additional information about the control module
currently being programmed. This information will be displayed as part of the device label on the display.
Pressing 2 while viewing Edit Control Screen #4 will cause the following screen to be displayed:
DESCRIPTION
NOUN/ADJECTIVE

Adjective/Noun Screen

1=REAR
2=UPPER
3=LOWER
Adjective Screen #3

1=FLOOR 4
2=FLOOR 5
3=ROOM
Adjective Screen #7

1=ELEVATOR
2=ENTRANCE
3=FLOOR
Noun Screen #3

1=STAIRWAY
2=STOREROOM
3=WING
Noun Screen #7
1M002
NFW-50X Manual — P/N LS10129-001NF-E:C 7/25/2018
Master Programming Level

1=MAIN
2=FIRST
3=2ND
Adjective Screen #4

1=GARAGE
2=HALLWAY
3=HVAC RM
Noun Screen #4

1=ZONE
Noun Screen #8

Advertisement

Table of Contents
loading

Table of Contents