1. Remove the module to be serviced from the server chassis and place it on an anti-static work surface
(see
Section
3.2.1).
2. Remove the riser assembly from Riser Slot 2 (see
3. Locate the TPM module connector on the server board.
4. Insert the plastic stand-off into the server board mounting hole (see Letter A).
5. Place the TPM module over the connector and confirm the orientation of the module.
6. Press the module down onto the connector (see Letter B).
7. Secure the TPM module to the stand-off with the fastener screw (see Letter C).
3.13 Ethernet Management Port Module (EMP Module) (iPC – AXXFCEMP)
Your system may or may not come preconfigured with an Ethernet Management Port Module. This section
provides instructions for the installation and removal of this accessory option. The EMP module is hot-swap
capable and can be installed or removed without powering down the system or any of its modules. This
procedure applies to all D50TNP chassis types.
1. If present, remove the EMP blank from the back of the server chassis by pulling it out from the chassis as
shown in
Figure
111.
2. Install the EMP module, by sliding it into the open EMP bay until it locks into place (see Letter A).
Intel® Server D50TNP Family Integration and Service Guide

Figure 111. Removing the EMP Blank

Figure 112. Installing the EMP Module/Blank