Sign In
Upload
Manuals
Brands
Intel Manuals
Motherboard
S2400SC
Intel S2400SC Manuals
Manuals and User Guides for Intel S2400SC. We have
2
Intel S2400SC manuals available for free PDF download: Technical Product Specification, Manual
Intel S2400SC Technical Product Specification (161 pages)
Brand:
Intel
| Category:
Server Board
| Size: 6.04 MB
Table of Contents
Oct 2012
2
Table of Contents
4
1 Introduction
13
Chapter Outline
13
Server Board Use Disclaimer
13
2 Overview
14
Intel ® Server Boards S2400SC Feature Set
14
Figure 2. Intel
14
Figure 11. Intel
14
Figure 12. Intel
14
Figure 22. Intel
14
Server Board Layout
16
Server Board Connector and Component Layout
16
Figure 1. Intel Server Board S2400SC Layout
16
Figure 2. Intel ® Server Board S2400SC Layout
17
Server Board Mechanical Drawings
19
Figure 3. Intel Server Board S2400SC - Mounting Hole Locations (1 of 2)
19
Figure 4. Intel Server Board S2400SC - Mounting Hole Locations (2 of 2)
20
Figure 5. Intel Server Boards S2400SC - Major Connector Pin-1 Locations (1 of 2)
21
Figure 6. Intel Server Boards S2400SC - Major Connector Pin-1 Locations (2 of 2)
22
Figure 7. Intel Server Boards S2400SC - Primary Side Keepout Zone
23
Figure 8. Intel Server Boards S2400SC - Primary Side Card Side Keepout Zone
24
Figure 9. Intel Server Boards S2400SC - Primary Side Air Duct Keepout Zone
25
Server Board Rear I/O Layout
26
Figure 10. Intel Server Boards S2400SC - Second Side Keepout Zone
26
3 Functional Architecture
28
Processor Support
28
Processor Socket Assembly
29
Processor Population Rules
29
Figure 13. Processor Socket Assembly
29
Table 3. Mixed Processor Configurations
30
Processor Function Overview
33
Intel ® Quickpath Interconnect
34
Integrated Memory Controller (IMC) and Memory Subsystem
34
Table 4. UDIMM Support Guidelines
35
Table 5. RDIMM Support Guidelines
36
Figure 14. Intel Server Board S2400SC DIMM Slot Layout
37
Table 1. Intel
37
Table 2. Intel
37
Processor Integrated I/O Module (IIO)
43
Figure 15. Functional Block Diagram of Processor IIO Sub-System
44
Intel C602-A Chipset Functional Overview
45
Figure 16. Functional Block Diagram - Chipset Supported Features and Functions
45
Table 7. External RJ45 NIC Port LED Definition
45
Digital Media Interface (DMI)
46
PCI Express* Interface
46
Serial ATA (SATA) Controller
46
Ahci
47
Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)
47
Low Pin Count (LPC) Interface
47
PCI Interface
47
Rapid Storage Technology
47
Serial Peripheral Interface (SPI)
47
Advanced Programmable Interrupt Controller (APIC)
48
Gigabit Ethernet Controller
48
Universal Serial Bus (USB) Controller
48
Enhanced Power Management
49
Gpio
49
Manageability
49
Rtc
49
Integrated NVSRAM Controller
50
Intel ® Active Management Technology (Intel ® AMT)
50
JTAG Boundary-Scan
50
Kvm/Serial over LAN (SOL) Function
50
System Management Bus (Smbus* 2.0)
50
VT-D)
50
On-Board Serial Attached SCSI (Sas)/Serial ATA (SATA) Support and Options
51
Table 6. Intel
51
Table 8. Intel
52
Integrated Baseboard Management Controller (BMC) Overview
53
Figure 17. Integrated Baseboard Management Controller (BMC) Overview
53
Figure 18. Integrated BMC Hardware
54
Super I/O Controller
54
Graphics Controller and Video Support
55
Table 9. Video Modes
55
Baseboard Management Controller
56
Table 10. Video Mode
56
4 System Security
58
BIOS Password Protection
58
Trusted Platform Module (TPM) Support
59
TPM Security BIOS
59
Physical Presence
60
TPM Security Setup Options
60
Figure 19. Setup Utility - TPM Configuration Screen
61
Intel Trusted Execution Technology
62
Table 11. TPM Setup Utility - Security Configuration Screen Fields
62
5 Technology Support
64
Intel Trusted Execution Technology
64
Intel Virtualization Technology - Intel
64
VT-X/Vt-D/Vt-C
64
Intel Intelligent Power Node Manager
65
Table 12. Intel Intelligent Power Node Manager
65
Hardware Requirements
66
6 Platform Management Functional Overview
67
Baseboard Management Controller (BMC) Firmware Feature Support
67
IPMI 2.0 Features
67
Non IPMI Features
68
New Manageability Features
69
Basic and Advanced Features
70
Table 13. Basic and Advanced Features
70
Integrated BMC Hardware: Emulex* Pilot III
71
Emulex* Pilot III Baseboard Management Controller Functionality
71
Advanced Configuration and Power Interface (ACPI)
72
Power Control Sources
72
Table 14. ACPI Power States
72
Table 15. Power Control Initiators
72
BMC Watchdog
73
Fault Resilient Booting (FRB)
73
Sensor Monitoring
74
Field Replaceable Unit (FRU) Inventory Device
74
System Event Log (SEL)
75
6.11 System Fan Management
75
Thermal and Acoustic Management
75
Setting Throttling Mode
76
Altitude
76
Set Fan Profile
76
Fan PWM Offset
76
Quiet Fan Idle Mode
76
Fan Profiles
77
Table 16. Fan Profiles
77
Thermal Sensor Input to Fan Speed Control
78
Memory Thermal Throttling
79
Figure 20. Fan Speed Control Process
79
6.12 Messaging Interfaces
80
User Model
80
IPMB Communication Interface
80
Table 17. Messaging Interfaces
80
LAN Interface
81
Address Resolution Protocol (ARP)
86
Internet Control Message Protocol (ICMP)
86
Virtual Local Area Network (VLAN)
86
Secure Shell (SSH)
87
Serial-Over-LAN (SOL 2.0)
87
Platform Event Filter (PEF)
88
LAN Alerting
88
Table 18. Factory Configured PEF Table Entries
88
Alert Policy Table
89
SM-CLP (SM-CLP Lite)
89
Embedded Web Server
90
Virtual Front Panel
91
Embedded Platform Debug
92
Table 19. Diagnostic Data
93
Data Center Management Interface (DCMI)
94
Lightweight Directory Authentication Protocol (LDAP)
94
Table 20. Additional Diagnostics on Error
94
7 Advanced Management Feature Support (RMM4)
95
Figure 21. Intel RMM4 Lite Activation Key Installation
95
Table 21. RMM4 Option Kits
95
Keyboard, Video, Mouse (KVM) Redirection
96
Remote Console
97
Performance
97
Security
97
Availability
98
Usage
98
Force-Enter BIOS Setup
98
Media Redirection
98
Availability
99
Network Port Usage
99
8 On-Board Connector/Header Overview
100
Board Connector Information
100
Table 22. Board Connector Matrix
100
Power Connectors
101
Table 23. Main Power Connector Pin-Out (J1H3)
101
Table 24. CPU 1/CPU 2 Power Connector Pin-Out (J5J2, J8A1)
101
Table 25. Power Supply Auxiliary Signal Connector Pin-Out (J1J2)
101
System Management Headers
102
Intel ® Remote Management Module 4 Connector
102
TPM Connector
102
Table 26. Intel RMM4 Connector Pin-Out (J1C7)
102
Table 27. Intel RMM4 - Lite Connector Pin-Out (J3D1)
102
Table 28. TPM Connector Pin-Out (J4J1)
102
LCP Header
103
HSBP Header
103
SATA SGPIO Header
103
Front Panel Connector
103
Table 29. LCP Header Pin-Out (J3J4)
103
Table 30. HSBP_I2C Header Pin-Out (J3J1)
103
Table 31. SATA SGPIO Header Pin-Out(J2J4)
103
I/O Connectors
104
VGA Connector
104
Table 32. Front Panel SSI Standard 24-Pin Connector Pin-Out (J1C3)
104
Table 33. VGA Connector Pin-Out (J7A2)
104
SATA Connectors
105
Table 34. SATA Connector Pin-Out (J1G1, J1F1, J2H1, J1H2, J1H1, J1G2)
105
Table 35. Minisas Connector Pin-Out (J1D3, J1E1)
105
Table 36. Minisas Connector Pin-Out (J1D3, J1E1)
105
Serial Port Connectors
106
USB Connector
106
Table 37. External DB9 Serial a Port Pin-Out (J8A2)
106
Table 38. Internal 9-Pin Serial B Header Pin-Out (J1B1)
106
Table 39. External USB Connector Pin-Out (U6A1, U7A1)
106
Fan Headers
107
Table 40. Internal USB Connector Pin-Out (J1C2)
107
Table 41. Pin-Out of Internal Low-Profile USB Connector for Solid State Drive (J2E1)
107
Table 42. Internal Type a USB Port Pin-Out (J1J1)
107
Table 43. SSI 4-Pin Fan Header Pin-Out (J5J1, J7A1, J9A1)
108
Table 44. SSI 6-Pin Fan Header Pin-Out (J2J5, J2J6, J2J7, J2J8, J3J2 and J3J3)
108
9 Jumper Blocks
109
Table 45. Server Board Jumpers (J1C4, J1C5, J1C6, J2J2, J2J3, J2J4))
109
BIOS Default (CMOS Clear) and Password Clear Usage Procedure
110
Clearing CMOS (BIOS Default)
110
Clearing the Password
111
Force BMC Update Procedure
111
ME Force Update Jumper
112
BIOS Recovery Jumper
112
10 Intel Light Guided Diagnostics
114
10.1 5 V Stand-By LED
114
Figure 23. 5 V Stand-By Status LED Location
114
10.2 Fan Fault Leds
115
Figure 24. Fan Fault LED Locations
115
10.3 CPU Fault Leds
116
Figure 25. CPU Fault LED Locations
116
10.4 System Status LED
117
Figure 26. System Status LED Location
117
Table 46. System Status LED
118
10.5 DIMM Fault Leds
120
Figure 27. DIMM Fault Leds Location
120
10.6 BMC Boot/Reset Status LED Indicators
121
Table 47. BMC Boot/Reset Status LED Indicators
121
10.7 Post Code Diagnostic Leds
122
Figure 28. POST Code Diagnostic LED Locations
122
11 Environmental Limits Specification
123
11.1 Processor Thermal Design Power (TDP) Support
123
Table 48. Server Board Design Specifications
123
11.2 Mtbf
124
11.3 Server Board Power Distribution
124
Figure 29. Power Distribution Block Diagram
125
Appendix A: Integration and Usage Tips
126
Appendix B: Integrated BMC Sensor Tables
127
Table 49. Integrated BMC Core Sensors
129
Appendix C: POST Code Diagnostic LED Decoder
145
Table 50. POST Progress Code LED Example
146
Table 51. POST Progress Codes
146
Table 52. MRC Progress Codes
148
Table 53. POST Progress LED Codes
149
Appendix D: POST Code Errors
150
Table 54. POST Error Codes and Messages
151
Table 55. POST Error Beep Codes
154
Table 56. Integrated BMC Beep Codes
155
Appendix E: Supported Intel Server Chassis
156
Table 57. Intel ® Server Chassis P4000S for S2400 Family
156
Table 58. Intel ® Server Chassis P4000M Family
156
Figure 30. Processor Heatsink Installation
157
Glossary
158
Reference Documents
161
Advertisement
Intel S2400SC Manual (141 pages)
EPSD Platform Based on Intel Xeon Processor E5 4600/2600/2400/1600/1400 Product families
Brand:
Intel
| Category:
Motherboard
| Size: 1.21 MB
Table of Contents
Revision History
2
Table of Contents
4
1 Introduction
11
Purpose
11
Industry Standard
12
Intelligent Platform Management Interface (IPMI)
12
Baseboard Management Controller (BMC)
12
Intel ® Intelligent Power Node Manager Version 2.0
13
2 Basic Decoding of a SEL Record
14
Default Values in the SEL Records
14
Table 1. SEL Record Format
14
Table 2: Event Request Message Event Data Field Contents
17
Table 3: OEM SEL Record (Type C0H-Dfh)
18
Table 4: OEM SEL Record (Type E0H-Ffh)
19
Notes on SEL Logs and Collecting SEL Information
20
Examples of Decoding BIOS Timestamp Events
20
Example of Decoding a PCI Express* Correctable Error Events
21
Example of Decoding a Power Supply Predictive Failure Event
22
3 Sensor Cross Reference List
23
BMC Owned Sensors (GID = 0020H)
23
Table 5: BMC Owned Sensors
23
BIOS POST Owned Sensors (GID = 0001H)
34
BIOS SMI Handler Owned Sensors (GID = 0033H)
34
Table 6: BIOS POST Owned Sensors
34
Table 7: BIOS SMI Handler Owned Sensors
34
Node Manager / ME Firmware Owned Sensors (GID = 002Ch or 602Ch)
35
Table 8: Management Engine Firmware Owned Sensors
35
Microsoft* os Owned Events (GID = 0041)
36
Linux* Kernel Panic Events (GID = 0021)
36
Table 9: Microsoft* os Owned Events
36
Table 10: Linux* Kernel Panic Events
36
4 Power Subsystems
37
Threshold-Based Voltage Sensors
37
Table 11: Threshold-Based Voltage Sensors Typical Characteristics
37
Table 12: Threshold-Based Voltage Sensors Event Triggers - Description
38
Table 13: Threshold-Based Voltage Sensors - Next Steps
38
Voltage Regulator Watchdog Timer Sensor
43
Voltage Regulator Watchdog Timer Sensor - Next Steps
44
Power Unit
44
Power Unit Status Sensor
44
Table 14: Voltage Regulator Watchdog Timer Sensor Typical Characteristics
44
Table 15: Power Unit Status Sensors Typical Characteristics
45
Table 16: Power Unit Status Sensor - Sensor Specific Offsets - Next Steps
45
Power Unit Redundancy Sensor
46
Table 17: Power Unit Redundancy Sensors Typical Characteristics
46
Node Auto Shutdown Sensor
47
Table 18: Power Unit Redundancy Sensor - Event Trigger Offset - Next Steps
47
Table 19: Node Auto Shutdown Sensor Typical Characteristics
47
Power Supply
48
Power Supply Status Sensors
48
Table 20: Power Supply Status Sensors Typical Characteristics
48
Table 21: Power Supply Status Sensor - Sensor Specific Offsets - Next Steps
49
Power Supply Power in Sensors
51
Table 22: Power Supply Power in Sensors Typical Characteristics
51
Table 23: Power Supply Power in Sensor - Event Trigger Offset - Next Steps
51
Power Supply Current out % Sensors
52
Table 24: Power Supply Current out % Sensors Typical Characteristics
52
Table 25: Power Supply Current out % Sensor - Event Trigger Offset - Next Steps
52
Power Supply Temperature Sensors
53
Table 26: Power Supply Temperature Sensors Typical Characteristics
53
Table 27: Power Supply Temperature Sensor - Event Trigger Offset - Next Steps
53
Power Supply Fan Tachometer Sensors
54
Table 28: Power Supply Fan Tachometer Sensors Typical Characteristics
54
5 Cooling Subsystem
55
Fan Sensors
55
Fan Tachometer Sensors
55
Table 29: Fan Tachometer Sensors Typical Characteristics
55
Fan Presence and Redundancy Sensors
56
Table 30: Fan Tachometer Sensor - Event Trigger Offset - Next Steps
56
Table 31: Fan Presence Sensors Typical Characteristics
56
Table 32: Fan Presence Sensors - Event Trigger Offset - Next Steps
57
Table 33: Fan Redundancy Sensors Typical Characteristics
57
Table 34: Fan Redundancy Sensor - Event Trigger Offset - Next Steps
58
Temperature Sensors
59
Threshold-Based Temperature Sensors
59
Table 35: Temperature Sensors Typical Characteristics
59
Table 36: Temperature Sensors Event Triggers - Description
60
Table 37: Temperature Sensors - Next Steps
60
Thermal Margin Sensors
61
Table 38: Thermal Margin Sensors Typical Characteristics
61
Table 39: Thermal Margin Sensors Event Triggers - Description
62
Table 40: Thermal Margin Sensors - Next Steps
62
Processor Thermal Control Sensors
63
Table 41: Processor Thermal Control Sensors Typical Characteristics
63
Table 42: Processor Thermal Control Sensors Event Triggers - Description
64
Processor DTS Thermal Margin Sensors
65
Discrete Thermal Sensors
65
Table 43: Processor DTS Thermal Margin Sensors Typical Characteristics
65
Table 44: Discrete Thermal Sensors Typical Characteristics
66
Table 45: Discrete Thermal Sensors - Next Steps
66
DIMM Thermal Trip Sensors
67
Table 46: DIMM Thermal Trip Typical Characteristics
67
System Air Flow Monitoring Sensor
68
6 Processor Subsystem
69
Processor Status Sensor
69
Table 47: Process Status Sensors Typical Characteristics
69
Table 48: Processor Status Sensors - Next Steps
70
Catastrophic Error Sensor
71
Table 49: Catastrophic Error Sensor Typical Characteristics
71
Table 50: Catastrophic Error Sensor - Event Data 2 Values - Next Steps
71
CPU Missing Sensor
72
Table 51: CPU Missing Sensor Typical Characteristics
72
CPU Missing Sensor - Next Steps
73
Quick Path Interconnect Sensors
73
QPI Link Width Reduced Sensor
73
Table 52: QPI Link Width Reduced Sensor Typical Characteristics
73
QPI Correctable Error Sensor
74
Table 53: QPI Correctable Error Sensor Typical Characteristics
74
QPI Fatal Error and Fatal Error #2
75
Table 54: QPI Fatal Error Sensor Typical Characteristics
75
Table 55: QPI Fatal #2 Error Sensor Typical Characteristics
76
Processor ERR2 Timeout Sensor
77
Processor ERR2 Timeout - Next Steps
78
Processor MSID Mismatch Sensor
78
Table 56: Processor ERR2 Timeout Sensor Typical Characteristics
78
Processor MSID Mismatch Sensor - Next Steps
79
Table 57: Processor MSID Mismatch Sensor Typical Characteristics
79
7 Memory Subsystem
80
Memory RAS Configuration Status
80
Table 58: Memory RAS Configuration Status Sensor Typical Characteristics
80
Table 59: Memory RAS Configuration Status Sensor - Event Trigger Offset - Next Steps
81
Memory RAS Mode Select
82
Table 60: Memory RAS Mode Select Sensor Typical Characteristics
82
Mirroring Redundancy State
83
Table 61: Mirroring Redundancy State Sensor Typical Characteristics
83
Mirroring Redundancy State Sensor - Next Steps
84
Sparing Redundancy State
84
Table 62: Sparing Redundancy State Sensor Typical Characteristics
85
Sparing Redundancy State Sensor - Next Steps
86
ECC and Address Parity
86
Memory Correctable and Uncorrectable ECC Error
86
Table 63: Correctable and Uncorrectable ECC Error Sensor Typical Characteristics
86
Memory Address Parity Error
88
Table 65: Address Parity Error Sensor Typical Characteristics
88
8 PCI Express* and Legacy PCI Subsystem
91
PCI Express* Errors
91
Legacy PCI Errors
91
Table 66: Legacy PCI Error Sensor Typical Characteristics
91
PCI Express* Fatal Errors and Fatal Error #2
92
Table 67: PCI Express* Fatal Error Sensor Typical Characteristics
92
Table 68: PCI Express* Fatal Error #2 Sensor Typical Characteristics
93
PCI Express* Correctable Errors
94
Table 69: PCI Express* Correctable Error Sensor Typical Characteristics
95
9 System BIOS Events
97
System Events
97
System Boot
97
Timestamp Clock Synchronization
97
Table 70: System Event Sensor Typical Characteristics
98
System Firmware Progress (Formerly Post Error)
99
System Firmware Progress (Formerly Post Error) - Next Steps
99
Table 71: POST Error Sensor Typical Characteristics
99
Table 72: POST Error Codes
100
10 Chassis Subsystem
107
Physical Security
107
Chassis Intrusion
107
LAN Leash Lost
107
Table 73: Physical Security Sensor Typical Characteristics
107
FP (NMI) Interrupt
108
Table 74: Physical Security Sensor Event Trigger Offset - Next Steps
108
FP (NMI) Interrupt - Next Steps
109
Table 75: FP (NMI) Interrupt Sensor Typical Characteristics
109
Button Sensor
110
Table 76: Button Sensor Typical Characteristics
110
11 Miscellaneous Events
111
IPMI Watchdog
111
Table 77: IPMI Watchdog Sensor Typical Characteristics
111
SMI Timeout
112
Table 78: IPMI Watchdog Sensor Event Trigger Offset - Next Steps
112
Table 79: SMI Timeout Sensor Typical Characteristics
112
SMI Timeout - Next Steps
113
System Event Log Cleared
113
Table 80: System Event Log Cleared Sensor Typical Characteristics
113
System Event - PEF Action
114
System Event - PEF Action - Next Steps
114
Table 81: System Event - PEF Action Sensor Typical Characteristics
114
BMC Watchdog Sensor
115
BMC Watchdog Sensor - Next Steps
115
Table 82: BMC Watchdog Sensor Typical Characteristics
115
BMC FW Health Sensor
116
BMC FW Health Sensor - Next Steps
116
Table 83: BMC FW Health Sensor Typical Characteristics
116
Firmware Update Status Sensor
117
Table 84: Firmware Update Status Sensor Typical Characteristics
117
Add-In Module Presence Sensor
118
Add-In Module Presence - Next Steps
118
Table 85: Add-In Module Presence Sensor Typical Characteristics
118
Intel ® Xeon Phi ™ Coprocessor Management Sensors
119
Intel ® Xeon Phi ™ Coprocessor (MIC) Thermal Margin Sensors
119
Intel ® Xeon Phi ™ Coprocessor (MIC) Status Sensors
119
Table 86: MIC Status Sensors - Typical Characteristics
119
12 Hot-Swap Controller Backplane Events
121
HSC Backplane Temperature Sensor
121
Table 87: HSC Backplane Temperature Sensor Typical Characteristics
121
Hard Disk Drive Monitoring Sensor
122
Table 88: HSC Backplane Temperature Sensor - Event Trigger Offset - Next Steps
122
Table 89: Hard Disk Drive Monitoring Sensor Typical Characteristics
122
Hot-Swap Controller Health Sensor
123
Table 90: Hard Disk Drive Monitoring Sensor - Event Trigger Offset - Next Steps
123
Table 91: HSC Health Sensor Typical Characteristics
123
HSC Health Sensor - Next Steps
124
13 Manageability Engine (ME) Events
125
ME Firmware Health Event
125
ME Firmware Health Event - Next Steps
125
Table 92: ME Firmware Health Event Sensor Typical Characteristics
125
Table 93: ME Firmware Health Event Sensor - Next Steps
126
Node Manager Exception Event
127
Node Manager Exception Event - Next Steps
127
Table 94: Node Manager Exception Sensor Typical Characteristics
127
Node Manager Health Event
128
Table 95: Node Manager Health Event Sensor Typical Characteristics
128
Node Manager Health Event - Next Steps
129
Node Manager Operational Capabilities Change
130
Table 96: Node Manager Operational Capabilities Change Sensor Typical Characteristics
130
Node Manager Operational Capabilities Change - Next Steps
131
Node Manger Alert Threshold Exceeded
132
Table 97: Node Manager Alert Threshold Exceeded Sensor Typical Characteristics
132
Node Manger Alert Threshold Exceeded - Next Steps
133
14 Microsoft Windows* Records
134
Boot up Event Records
134
Table 98: Boot up Event Record Typical Characteristics
134
Table 99: Boot up OEM Event Record Typical Characteristics
135
Shutdown Event Records
136
Table 100: Shutdown Reason Code Event Record Typical Characteristics
136
Table 101: Shutdown Reason OEM Event Record Typical Characteristics
136
Table 102: Shutdown Comment OEM Event Record Typical Characteristics
137
Bug Check / Blue Screen Event Records
138
Table 103: Bug Check/Blue Screen - os Stop Event Record Typical Characteristics
138
Table 104: Bug Check/Blue Screen Code OEM Event Record Typical Characteristics
139
15 Linux* Kernel Panic Records
140
Table 105: Linux* Kernel Panic Event Record Characteristics
140
Table 106: Linux* Kernel Panic String Extended Record Characteristics
141
Advertisement
Related Products
Intel S2400GP
Intel S2400LP
Intel S2400BB
Intel S2400EP
Intel S2600IP4
Intel S2600GL
Intel S2600IP
Intel S2600JF
Intel S2600WP
intel S2600KPFR
Intel Categories
Motherboard
Computer Hardware
Server
Server Board
Desktop
More Intel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL