Intel® Server D50TNP Family Integration and Service Guide
2.6.1
Storage Module Installation (iPC – D50TNP2MHSTAC Only)
Important: When installing an Intel® Storage Module in the chassis for the very first time, the internal chassis
rails need to be removed.
Required Tools and Supplies:
Anti-static wrist strap and conductive workbench pad (recommended)

Figure 55. Removing the Internal Chassis Rail

1. Locate the internal rails in the upper part of the inner wall, both sides of the chassis.
2. Release the rail latch (see Letter A).
3. Slide the rail towards the front of the chassis to remove it (see Letter B).
Do not reinstall the internal chassis rails if the chassis is used only for Intel® Storage Module. For any other
type of module installation, the internal chassis rails need to be reinstalled. Follow the instructions below to
reinstall the internal chassis rails.

Figure 56. Installing the Internal Chassis Rail

4. Place the new rail inside the chassis, aligning the keying pins of the rail with the chassis inner wall.
5. Slide the rail into the chassis inner wall towards the back of the chassis until it locks into place.