Validated chassis

The following chassis have been validated by Matrox to work with Matrox Mura IPX Series, Matrox D1480, and Matrox D1450 products.
Note:
For improved performance, we recommend you avoid using PCIe

Currently supported chassis

Advantech ACP-4010

Cards supported
(maximum)
Part number
Power supply
Power supply bracket
Fan
Supported motherboards
Notes

Advantech ACP-4000

Cards supported
(maximum)
Part number
Power supply
Power supply bracket
Fan
Supported motherboards
Notes
76
Matrox Display Wall – System Builder's Guide
7
ACP-4010MB-00BE/ACP-4010MB-00C (includes chassis and standard 82 CFM chassis fans)
750 W redundant power supply (Advantech P/N: RPS8-750ATX-XE)
Standard
Two 120 mm x 120 mm x 25 mm 150 CFM fans (must upgrade from 82 CFM standard fans to 150 CFM fans)
Advantech ASMB-815
ASUS PRO WS X299 SAGE II
ASUS WS C621E SAGE
Power supply is not included with the chassis. It must be purchased separately.
The standard 82 CFM chassis fans must be replaced with two 120 mm x 120 mm x 25 mm 150 CFM fans
that must be purchased separately.
The chassis fans are connected directly to the motherboard and must run at full speed. To change the fan
speed, go to the system BIOS main page (EZ mode)  select
fans are connected
change from
Two dust protection sponge filters present on the front door and in front of the fans must be removed for
proper system ventilation.
If you use a wired mesh filter, the ambient temperature is limited to 40 degree centigrade. Filter requires a
18 x 18 size 304 stainless steel wire mesh.
5
ACP-4000MB-00XE / ACP-4000MB-00F (includes chassis and standard 82 CFM chassis fans)
Advantech FSP700-80PSA (P/N:96PS-A700WPS2)
Standard
Two 120 mm x 120 mm x 25 mm 150 CFM standard cooling fans (must upgrade from 82 CFM standard fans
to 150 CFM fans)
Advantech ASMB-815
Power supply is not included with the chassis. It must be purchased separately.
The standard chassis fans must be replaced with two 120mm x 120mm x 25mm 150 CFM fans that must
be purchased separately.
The dust protection sponge filter in front of the chassis must be removed for proper system ventilation
when the smart fan is enabled.
If you use a wired mesh filter in front of the chassis, the smart fan must be disabled. The chassis fans must
run at full speed.
Filter requires a 18 x 18 size 304 stainless steel wire mesh.
Advanced  IT8528 HW Monitor Tab  Fan Configuration Tab 
In the system BIOS, go to
which the chassis fans are connected
 Enabled
(when dust protection filter is removed)
 Disabled
(when wired mesh filter is present)
®
4 slots or lower.
×
QFan Control
to
and apply the changes.
Standard
Full Speed
select
Smart Fan Mode:
 select the header to which the
select the header to