Operational Errors - JCM GLOBAL TBV-100 FSH Quick Reference Manual

Hide thumbs Also See for TBV-100 FSH:
Table of Contents

Advertisement

O
PERATIONAL
Operational Errors are indicated by the number of
Note the number of flashes between pauses to identify the Error
(Table 10).
NOTE: Refer to the TBV
Operation and Maintenance Manual (JCM P/N 960-100926R)
for a full description of errors and corrective actions.
RED
Flashes
1
2
3
Stacker Motor Lockup
4
Centering Motor Lockup
5
6
7
8
9
Pusher Plate Half way
10
Centering Home Sensor
11
12
BNF Communications
13
ICB Communications
14
© 2019 JCM Global Corporation
TBV™-100/101 Units
E
RRORS
Table 10 Operational Error Codes
Error Type
Cash Box Full
Feed Motor Lockup
BNF Unit
Shutter Error
Banknote Jam,
Pusher Mechanism
Pusher Mechanism
Home Sensor
Feed Motor Speed
Voltage
Series Transaction Based Validator
Detected a Cash Box Full condition.
Feed Motor encoder pulses not
detected.
Stacker Motor encoder pulses not
detected.
Centering Motor encoder pulses not
detected.
BNF Sensors detected abnormal
movement.
Shutter Sensors detected abnormal
movement.
Pusher Mechanism home sensor is not
detected.
The Pusher Home Sensor is not
detected.
The Pusher Plate is not returning to the
halfway position.
Centering Home Mechanism is not
returning to the home position.
Motor encoder pulses out of range.
Detected communications data transfer
rate improper.
ICB Communications abnormal.
Input voltage is too low.
17
RED
LED flashes.
Cause
Part No. 960-000207R_Rev. A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents