ID61/62 Series Panel - Installation, Commissioning & Configuration Manual
The first 30 modules (from
lowest address upwards)
restricted to types MCP, DKM,
MRL, IRL and all AUX actions
except Plant Alarm, are added
automatically to a priority poll
list. Subsequent modules are
polled normally.
EN 54-2 : 7.6.1, 7.8
Level 2 Keyswitch access
MUST be used with an input
Type AUX panel Reset (7.6.1)
& Silence/Resound (7.8).
CAUTION:
This product is not compliant
EN
EN
12094-1
12094-1
with EN 12094-1.
!
!
Fire extinguishing installations in
Europe are required to be certified as
compliant to this standard.
2
or
2
1
Non-monitored outputs
If 'TxD' is selected refer to the Operating
2
Manual, Section 4.12.7 Voltages - User
Option to set the transmission circuit
reference impedance to enable correct
fault monitoring.
997-457-000-8, Issue 8
January 2010
5.6.1.3 Type Setting
Standard input modules in zones 1 to 16 can be assigned
to various types as shown below. A Manual Call Point (MCP)
input has the action of a zone fire alarm 'Manual Call Point'
with prioritized polling. A Fire Alarm Monitor (MON) input
has the action of a zone fire alarm with non-prioritized polling.
An input module assigned to a zone in the range 17 to 32 is
automatically given the type AUX, for a plant alarm input.
Input devices of type AUX can be programmed for plant
alarm, reset panel, silence sounders, mute buzzer, class
change, (only used when Class Change input has been
configured for Day Mode start), abort switch, hold switch,
Extinguishing System released and Extinguishing System
fault (the last four cases are functions associated with
the configuration of Extinguishing System inputs).
The device type is configured during the learn process.
Sensor types and Plant Warning inputs (AUX) cannot be
changed. The 'Type' menu option is not shown on the
display for these devices.
Monitored output modules can be assigned to various
types as shown below.
To change the module type as displayed on the LCD:
1 Using the numeric keypad press '
[Module nn - MCP] 1 : Zone (nn)
[Module nn - SDR] 1 : Zone (nn)
3 : CBE Rule (nn) 4 : [
2 Selecting the Type option displays one of the following:
[Module nn - MCP] Select Type :
>MCP< DKM MON MNS MRL IRL
[Module nn - ZMX] Select Type :
>ZMX< FRM
[Module nn - SDR] Select Type :
>SDR< CTL RLY EST ESO ESM TxD ESE RLE CTE S
8
Note: On-Board circuits 1, 2, 3 and 4 support SDR, SDH,
3 Select the module type using the press the '
[Module nn - MCP] 1 : Zone (nn)
3 : CBE Rule (nn)
70
from the menu displaying the module attributes:
4 : [
Blank/Existing Text
Blank/Existing Text
RLY
1
, CTL, TxD
2
, RLE
1
, CTE, EST
Output Circuits. On-Board circuits 5 and 6 are fixed
as Unmonitored -VE Output circuits.
buttons to cycle through the list of modules and select
the new type. The LCD then displays the new module
attributes menu. A typical menu is shown below:
4 : [ Blank/Existing Text
' (Type option)
2
2 : Type
]
2 : Type
]
<: Cancel
<: Cancel
1
, ESO and ESE
1
/
'
2
8
2 : Type
]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Notifier id61

Table of Contents