DISPLAYED PARAMETERS ONLY IF OPTIONAL MEMORY INSTALLED
dAt. L oG.
DATALOGGER [1005]
Allows you to save the weight and I/O status in the optional memory in Excel format. The logging can
be a single measurement or a continuous series of measurements from the start of storage (max 1000
measurements). The memory can contain a maximum of 60000 records, after which the oldest records
are overwritten.
Selectable setting:
NONE [0]
SINGLE [1]
CONTIN. [2]
Default: NONE
LoG. t rG.
TRIGGER DATALOGGER [1006]
If the datalogger is enabled, select whether storage is done manually (by button or input), or on activa-
tion of output 1 or 2. To start storing by key, press and hold the SET button. Storage can be interrupted
at any time by pressing the ZERO key.
Selectable setting:
MANUAL [0]
OUT1 [1]
OUT2 [2]
Default: MANUAL
LoG. F rQ.
DATALOGGER FREQUENCY [1007]
If the datalogger is enabled, select the storage frequency of data (datalogger). The maximum frequency
corresponds to that of weight acquisition (maximum frequency 250 Hz).
Selectable setting:
10 MIN. [0]
5 MIN. [1]
1 MIN. [2]
10 SEC. [3]
5 SEC. [4]
2 SEC. [5]
1 HZ [6]
5 HZ [7]
10 HZ [8]
HIGH [9]
Default: 10 MIN.