Analog Parameters - Pavone Systems DAT11 Technical Manual

Serial and analog weighing indicator/trasnmitter
Table of Contents

Advertisement

ANALOG - ANALOG OUTPUT PARAMETERS (OPTIONAL)
rAnGE. .
ANALOG OUTPUT RANGE [1506]
Select the analogue output range.
Selectable setting:
0÷10 Vdc [0]
0÷5 Vdc [1]
4÷20 mA [2]
0÷20 mA [3]
Default: 0÷10 Vdc
NodE. .
ANALOG OUTPUT OPERATION MODE [1505]
Selection of the value to be associated to the analogue output, corresponding to the net weight, gross
weight or peak value.
Selectable setting:
NET [0]
GROSS [1]
PEAK [2]
HOLD [3]
Default: NET
An 0. .
ANALOG OUTPUT ZERO VALUE [1501-1502]
Analogue value to be subtracted referred to the full scale of the analogue output.
An FS. .
FULL SCALE [1503-1504]
It is the weight corresponding to the analog output full scale.
Value settable from 0 to Capacity
Default: Capacity
0 AdJ. .
ZERO OFFSET REGULATION
Measure the analogue output value with a multimeter to perform the zero (0) calibration.
Use the keys
and
to regulate the analogue output. Press and hold the key for rapid change.
Press key
to go back to the ANALOG menu.
Page 32