Pavone Systems DAT11 Technical Manual page 52

Serial and analog weighing indicator/trasnmitter
Table of Contents

Advertisement

AJErAG.
NUMBER OF READINGS ON AVERAGE [1203]
With this parameter you set the number of readings that the filter will use to establish the average
weight value.
Values: from 0 to 50.
Nonot.
MONOTONY TIME [1204
Parameter used to stabilize the weight when continuous variation of the last digit is detected. Normally
used in case of resolution of the weight exceeding 10,000 divisions or with low sensitivity of the input
signal. Value expressed in mS.
Values: from 0 to 999.
t. o SC1L. .
OSCILLATIONS TIME [1205]
Parameter used in conjunction with oscillation Range to reduce the lens weight changes and repetitive
typical in lifting systems. Enter the value of the oscillation time expressed in mS.
Values: from 0 to 999.
r. o SC1L.
OSCILLATIONS RANGE [1206]
As for the parameter Oscillation time, used to reduce the oscillations. Enter the value of the oscillation
expressed in weight divisions.
Values: from 0 to 99.
Page 50

Advertisement

Table of Contents
loading

Table of Contents