Pavone Systems DAT11 Technical Manual page 33

Serial and analog weighing indicator/trasnmitter
Table of Contents

Advertisement

The linearisation points are automatically reset by any change of the theoretical calibration data or if
a full-scale calibration is performed.
It allows you to manually program up to five calibration points, in addition to zero. The values corre-
sponding to those resulting from the linearisation procedure with sample weights. This way you can view
the values automatically determined with this procedure or modify and program them in accordance
with predetermined values.
SUB-MENU
MESSAGGIO
0 S1G.
P1 JAL.
P1 S1G.
P2 JAL.
P2 S1G.
P3 JAL.
tAbLE
P3 S1G.
P4 JAL.
P4 S1G.
P5 JAL.
P5 S1G.
GEt
The programmed to zero are not considered. The calibration data sheet is automatically cancelled when
a new theoretical calibration is carried out or with sample weights.
After the execution of the zero signal acquisition function, using
recalculated. At each signal value an offset is added, obtained from the difference between the new
acquired zero signal and the old zero signal value.
EXITING THE CALIBRATION MENU
To exit the CAL1b press the menu key
Press ENTER again to save calibration and exit the setup menu.
TABLE CALIBRATION
NAME
Zero signal
Weight point 1
Signal point 1
Weight point 2
Signal point 2
Weight point 3
Signal point 3
Weight point 4
Signal point 4
Weight point 5
Signal point 5
Acquire the
0
Zero Signal
, press until the text storE? appears on the display.
DESCRIPTION
Signal value in mV / V corresponding to
the zero scale
Weight value corresponding to the 1st
calibration point
Signal value in mV/V corresponding to the
1st calibration point
Weight value corresponding to the 2nd
calibration point
Signal value in mV/V corresponding to the
2nd calibration point
Weight value corresponding to the 3rd
calibration point
Signal value in mV/V corresponding to the
3rd calibration point
Weight point 4 Weight value corresponding
to the 4th calibration point
Signal point 4 Signal value in mV/V
corresponding to the 4th calibration point
Weight point 5 Weight value corresponding
to the 5th calibration point
Signal point 5 Signal value in mV/V
corresponding to the 5th calibration point
Acquisition function of the signal
corresponding to the zero scale expressed
in mV/V
key, the signals in the table are
TYPE
Com.
Com.
Com.
Com.
Com.
Com.
Com.
Com.
Com.
Com.
Com.
Page 31