Pavone Systems DAT11 Technical Manual page 41

Serial and analog weighing indicator/trasnmitter
Table of Contents

Advertisement

PARAMETERS COM 2 WHEN ETHERNET IP IS PRESENT
En. F buS.
FIELDBUS ENABLING
Enabling ETHERNET IP fieldbus, if OFF error messages concerning Fieldbus communication are never
displayed:
Values that can be selected:
OFF
ON
Default: OFF
1P
IP ADDRESS
ETHERNET IP protocol address
Values from 0.0.0.0 to 255.255.255.255
Default: 0.0.0.0
SubnEt
SUBNET MASK
ETHERNET IP protocol Subnet Mask.
Values from 0.0.0.0 to 255.255.255.255
Default: 0.0.0.0
InP. r EG. .
INPUT AREA DIMENSION
Input area dimension for fieldbus (value expressed in Bytes).
Values that can be selected:
32, 64, 96, 128
Default: 128
oUt. r EG. .
OUTPUT AREA DIMENSION
Output area dimension for fieldbus (value expressed in Bytes).
Values that can be selected:
32, 64, 96, 128
Default: 128
In the case of IP ETHERNET fieldbus, the EDS configuration file "HILSCHER NIC 50-RE EIS V1.1.EDS" is
provided. The size of the input and output areas set in the PLC (possible selections: 32, 64, 96 or 128
bytes) must correspond to the size of the input and output areas selected in the instrument (parameters
"INP.REG." and "OUT .REG.").
Page 39