Electric scissor lifts
G
- Technical characteristics
4 -
AS - CE standard specificities
The following tests must be performed after :
• A major technical intervention.
• An accident due to major component failure on the machine.
• The following tests must be performed by a qualified person in secure conditions.
• The results must be fully recorded.
To avoid the machine tipping over, it must be secured during the test (by a chain or anchorage point).
4.1 -
OVERLOAD TEST
Load table
COMPACT 8 (COMPACT 2032E)
COMPACT 14 (COMPACT 3947E)
COMPACT 8W (COMPACT 2247E)
COMPACT 10 (COMPACT 2747E)
COMPACT 12RTE (COMPACT 3368RTE)
COMPACT 10N (COMPACT 2632E)
OPTIMUM 8 (OPTIMUM 1930E)
COMPACT 10N-1 (NA)
OPTIMUM 8-1 (NA)
COMPACT 12 (COMPACT 3347E)
COMPACT 8CU (NA)
OPTIMUM 6 (OPTIMUM 1530E)
COMPACT 10RTE (COMPACT 2668RTE)
The machine must not show any signs of permanent distortion.
Tests are performed by a qualified person under optimal conditions and results must be fully recorded.
4.2 -
FUNCTIONAL TEST
Functional tests have confirmed the following: :
• The machine has performed all movements without jerking, while carrying the nominal load.
• All security systems are operating correctly.
• Maximum authorized operating speeds are not exceeded.
2420332270
Machine
e10 12
Test load
Pound (lb)
Kilogramme (kg)
965
1240
634
331
827
744
1557
437,5
562,5
287,5
150
375
337,5
706,25
125
EN
A
B
C
D
E
F
G
H
I