Extron electronics FOX3 SR 20 User Manual page 25

Fiber optic hdmi scaling receiver
Table of Contents

Advertisement

Perform resets of the unit as follows:
Mode 1
Mode 4
Mode 5
Figure 14.
Mode
Activation
1
Hold in the recessed rear panel
Reset button while applying
power.
NOTE:
Do not operate with the default firmware loaded by a mode 1 reset. Use it only to load the most current
firmware to the device.
*4
Hold in the Reset button about
6 seconds until the Power LED
blinks twice. Then, release
and press the Reset button
momentarily (<1 second) again
within 1 second.
*5
Hold in the Reset button until
the Power LED blinks three times
(once at 3 seconds, again at
6 seconds, again at 9 seconds).
Then, release and press the
Reset button again within
1 second*.
NOTES:
*For modes 4 and 5, nothing happens if the momentary press does not occur within 1 second.
The factory configured passwords for all accounts on this device have been set to the device serial
number. In the event of a complete system reset, the passwords convert to the default, which is
extron
.
RESET
Press and hold
the Reset button.
Reset LED flashes twice.
RESET
Press and hold
for 6 seconds.
Reset LED flashes three
times.
RESET
Press and hold
for 9 seconds.
Resets
Reset Modes
Result
The device reverts to the factory default
firmware for a single power cycle.
Sets the following back to factory default:
Port mapping
IP address: 192.168.254.254
Subnet mask address:
255.255.255.0
Gateway address: 0.0.0.0
Turns DHCP off.
Power LED blinks 4 times during reset.
A complete reset to factory defaults
(except the firmware).
Does everything mode 4 does.
Clears port configurations.
Resets all IP options.
Clears all user settings.
Clears all files from the unit.
Power LED blinks four times.
RESET
Apply power
Release Reset button.
to the FOX3.
Release, then immediately
press and release again.
Reset LED flashes, then stays on.
RESET
RESET
Release, then immediately
press and release again.
Reset LED flashes, then stays on.
RESET
RESET
Purpose and Notes
Use to revert to the factory default
firmware for a single power cycle if
incompatibility issues arise with user-
loaded firmware. All user files and
settings are maintained.
Use to reset all IP settings back to
the factory defaults.
Equivalent to SIS command 1ZQQQ.
Mode 5 is useful to start over with
default configuration and uploading,
and also to replace events.
Mode 5 is equivalent to SIS
command ZQQQ.
FOX3 SR 201 Scaling Receiver • Operation
17

Advertisement

Table of Contents
loading

Table of Contents