Extron electronics FOX3 SR 20 User Manual page 36

Fiber optic hdmi scaling receiver
Table of Contents

Advertisement

Command Function
Information requests (continued)
Information request
Verbose mode 2/3:
Example:
X$
= Input video signal status
KEY:
X^
= Input HDCP status
X&
= Output HDCP status
X*
= Input audio selection
X(
= Device type
X2*
= Fiber link detection
X2(
= Fiber optic mode
DHCP client
Set DHCP on or off
View DHCP status
X1)
KEY:
= Set DHCP
Telnet port
Set Telnet port map
View Telnet port map
X3%
= Enable Telnet port 23
KEY:
X3^
= Port number
Echo for SIS over SSH (port 22023)
Enable Echo
Disable Echo
View Echo status
NOTE:
The echo setting is for the current connection only, and remains until the connection is closed. Apply after connection is established.
X3)
KEY:
= Off or on
Verbose mode
Set verbose mode
View verbose mode
NOTE:
Verbose mode will revert back to default in the event of a power cycle, disconnect from dataviewer, or disconnect from the Ethernet.
X1&
KEY:
= Verbose mode
Timeout Ethernet data port
Set current port timeout
View current port timeout
X3!
KEY:
= Timeout
SIS Command
(Host to Unit)
I
SFPALnk
Inf00*SFPALnk
Response description:
Fiber link A•Fiber link B•Signal input•Input HDCP•Output HDCP•Input audio•Receiver•Fiber mode
I
0
= Not detected
0
= No source detected
2
= Source with no HDCP present
0
= No active sink detected
2
= Sink detected, output signal not encrypted
0
= Auto
TX
RX
or
0
= Not detected
SM
MM
or
E X1)
}
DH
E
}
DH
0
= Off (default)
E
X3%
}
Z
PMAP
E
}
ZPMAP
0
= Off (default)
Response is 5 digits with leading zeros, for example
E
}
1ECHO
E
}
0ECHO
E
}
ECHO
0
= Off
E X1&
}
CV
E
}
CV
0
= Clear/none (default for Ethernet)
2
= Tagged response for queries
E
X3!
}
0*
TC
E
}
0TC
The number of seconds before timeout on IP connections (min=
30
300
10 seconds [default=
=
seconds])
FOX3 SR 201 Scaling Receiver • SIS Configuration and Control
Response
Additional description
(Unit to Host)
X2*
X2*
X$
SFPBLnk
SigI
X2*
X2*
X$
SFPBLnk
SigI
HdcpI
SFPALnk1 • SFPBLnk1 • SigI1 • HdcpI1 • HdcpO1 • AudI1 • RX • SM
Signals are detected on the two fiber links, a signal is detected on the
input, the input and output are HDCP devices, the digital audio input is
selected, the device is a receiver, and the fiber mode is singlemode.
1
= Detected
1
= Source with HDCP detected (default)
1
= Sink detected, output signal encrypted
1
2
= Digital
1
= Detected
X1)]
Idh
X1)]
1
= On
X3^]
PmapZ
X3^]
23
= Telnet port 23 enabled
00000
]
Echo1
Returns command entered with
response.
]
Echo0
Returns response only.
X3)]
1
= On (default)
X1&]
Vrb
X1&]
1
= Verbose mode (default for RS-232)
3
= Verbose mode and tagged responses for queries
X3!]
Pti0*
X3!]
1
, max=
X^
X&
X*
X(
HdcpI
HdcpO
AudI
X^
X&
X*
X(
X2(]
HdcpO
AudI
= Analog
00023
or
650000
, with each number equivalent to
X2(]
]
]
28

Advertisement

Table of Contents
loading

Table of Contents