Tightening torques for screws

Table 42:
Tightening torques for screws
Threads
M6
M8
M10
M12
M16
M20
M30
M36
SAR 16.2 Control unit - electromechanical
For actuator controls mounted separately from the actuator, including plug/socket connector.
Connecting cable on request.
Recommended for high ambient temperatures, difficult access, or in case of heavy vibration during
service.
Cable length between actuator and actuator controls is max. 100 m. An MWG is required for position
feedback.
AUMA CDT (Commissioning and Diagnostic Tool for Windows-based PC)
AUMA Assistant App (Commissioning and Diagnostic Tool for Android devices)
Accessory for torque measurement for SA/SAR 07.2
Approx. 7 kg (with AUMA plug/socket connector)
Machinery Directive 2006/42/EC
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
A2-70/A4-70
7.4
18
36
61
150
294
1,015
1,769
SA/SAR 16.2
Tightening torque [Nm]
Strength class
Technical data
A2-80/A4-80
10
24
48
82
200
392
1,057
2,121
87