AUMA SA 07.2 Operation Instructions Manual page 11

Multi-turn actuators control unit - electromechanical with actuator controls
Hide thumbs Also See for SA 07.2:
Table of Contents

Advertisement

SA 07.2
SA 16.2/SAR 07.2
AC 01.2 Intrusive Modbus RTU
Type designation
Order number
Actuator serial number
Actuator terminal plan
AUMA power class for
switchgear
Control
SAR 16.2 Control unit - electromechanical
Descriptions referring to name plate indications
Table 1:
Description of type designation (with the example of SA 07.2-F07)
07.2
-F10
Type SA = Multi-turn actuators for open-close duty
Type SAR = Multi-turn actuators for modulating duty
07.2
Size
These instructions apply to sizes 07.2, 07.6, 10.2, 14.2, 14.6, 16.2
F10
Flange size
Table 2:
Description of actuator controls type designation (with the example of AC 01.2)
AC
01.2
AC
Type AC = AUMATIC actuator controls
01.2
Size 01.2
The product can be identified using this number and the technical data as well as
order-related data pertaining to the device can be requested.
Please always state this number for any product inquiries.
On the Internet at http://www.auma.com > Service & Support >myAUMA, we offer
a service allowing authorised users to download order-related documents such as
wiring diagrams and technical data (both in German and English), inspection certificate
and the operation instructions when entering the order number.
Table 3:
Description of serial number (example of 0520MD12345)
05
20
MD12345
05
Positions 1+2: Assembly in week = week 05
20
Positions 3+4: Year of manufacture = 2020
MD12345
Internal number for unambiguous product identification
Position 9 after TPA: Position transmitter version
0 = without position transmitter
A, B, J, K, L, N, R, T = potentiometer
C, D, E, G, H, M, P, S, U = Electronic position transmitter
The switchgear used in the actuator controls (reversing contactors/thyristors) are
classified according to AUMA power classes (e.g. A1, B1, ....). The power class
defines the max. permissible rated power (of the motor) the switchgear has been
designed for. The rated power (nominal power) of the actuator motor is indicated in
kW on the motor name plate. For the assignment of the AUMA power classes to the
nominal power of the motor types, refer to the separate electrical data sheets.
For switchgear without assignment to any power classes, the actuator controls name
plate does not indicate the power class but the max. rated power in kW.
Table 4:
Control examples (indications on actuator controls name plate)
Input signal
Description
Modbus RTU
Control vie Modbus RTU interface
Modbus RTU/24 V DC
Control via Modbus RTU interface and control voltage for OPEN-CLOSE
control via digital inputs (OPEN, STOP, CLOSE)
Name plate
11