AUMA SAR 16.2 Operation Instructions Manual

AUMA SAR 16.2 Operation Instructions Manual

Multi-turn actuators control unit - electromechanical with actuator controls ac 01.2 intrusive
Hide thumbs Also See for SAR 16.2:
Table of Contents

Advertisement

Multi-turn actuators
SA 07.2
SA 16.2
SAR 07.2
SAR 16.2
Control unit - electromechanical
with actuator controls
AC 01.2 Intrusive
Control
Parallel
Profibus DP
Profinet
Modbus RTU
Modbus TCP/IP
Foundation Fieldbus
HART
Operation instructions
Assembly, operation, commissioning

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAR 16.2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AUMA SAR 16.2

  • Page 1 Multi-turn actuators SA 07.2 SA 16.2 SAR 07.2 SAR 16.2 Control unit - electromechanical with actuator controls AC 01.2 Intrusive Control Parallel Profibus DP Profinet Modbus RTU Modbus TCP/IP Foundation Fieldbus HART Operation instructions Assembly, operation, commissioning...
  • Page 2: Table Of Contents

    Reference documents: Manual (Operation and setting ) of actuator controls AC 01.2 Parallel Reference documents can be downloaded from the Internet (www.auma.com) or ordered directly from AUMA (refer to <Addresses>). Table of contents Page Safety instructions.........................
  • Page 3 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Table of contents 5.2.3. Terminal compartment : close 5.3. Accessories for electrical connection 5.3.1. Actuator controls on wall bracket 5.3.2. Parking frame 5.3.3. DS intermediate frame for double sealing 5.3.4.
  • Page 4 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Table of contents AC 01.2 Intrusive 9.7. Switch compartment: close Commissioning (optional equipment settings)..............10.1. EWG 01.1 electronic position transmitter 10.1.1. Measuring range: set 10.1.2. Current values : adjust 10.1.3.
  • Page 5: Safety Instructions

    Any device modification requires prior written consent of the manufacturer. 1.2. Range of application AUMA multi-turn actuators are designed for the operation of industrial valves, e.g. globe valves, gate valves, butterfly valves, and ball valves. Other applications require explicit (written) confirmation by the manufacturer.
  • Page 6: Applications In Ex Zone 22 (Option)

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Safety instructions AC 01.2 Intrusive Escalators Continuous duty Buried service Continuous submersion (observe enclosure protection) Potentially explosive areas, with the exception of zone 22 Radiation exposed areas in nuclear power plants No liability can be assumed for inappropriate or unintended use.
  • Page 7: References And Symbols

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Safety instructions Indicates an imminently hazardous situation with a high level of risk. Failure to observe this warning could result in death or serious injury.
  • Page 8: Identification

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Identification AC 01.2 Intrusive Identification 2.1. Name plate Figure 1: Arrangement of name plates Actuator name plate Actuator controls name plate Motor name plate Additional plate, e.g. KKS plate (Power Plant Classification System)
  • Page 9 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Identification Actuator controls name plate Figure 3: Name plate for actuator controls (example) Type designation Order number Serial number Actuator terminal plan Actuator controls terminal plan...
  • Page 10 The rated power (nominal power) of the actuator motor is indicated in kW on the motor name plate. For the assignment of the AUMA power classes to the nominal power of the motor types, refer to the separate electrical data sheets.
  • Page 11: Short Description

    (push buttons and display) and perform settings (contents of these instructions). read in or out data or modify and save settings via AUMA CDT software (ac- cessory), using a computer (laptop or PC). The connection between computer and actuator controls is wireless via Bluetooth interface (not included in these instructions).
  • Page 12: Transport, Storage And Packaging

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Transport, storage and packaging AC 01.2 Intrusive Transport, storage and packaging 3.1. Transport For transport to place of installation, use sturdy packaging. Hovering load! Risk of death or serious injury.
  • Page 13 SAR 16.2 AD... Refer to motor name plate Indicated weight includes AUMA NORM multi-turn actuator with 3-phase AC motor, electrical con- nection in standard version, output drive type B1 and handwheel. For other output drive types, heed additional weights. Table 4: Weights for multi-turn actuators SA 07.2...
  • Page 14: Storage

    FN... 100-... SAR 16.2 Refer to motor name plate Indicated weight includes AUMA NORM multi-turn actuator with DC motor, electrical connection in standard version, output drive type B1 and handwheel. For other output drive types, heed additional weights. Table 6: Weights for output drive type A 07.2...
  • Page 15 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Transport, storage and packaging cardboard, paper, and PE foil. For the disposal of the packaging material, we recommend recycling and collection centres.
  • Page 16: Assembly

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Assembly AC 01.2 Intrusive Assembly 4.1. Mounting position The product described in this document can be operated in any mounting position. Restriction: When using oil instead of grease within the actuator gear housing, the hollow shaft mounting position must be perpendicular, with the flange pointing downward.
  • Page 17: 4.3.1.1. Stem Nut: Finish Machining

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Assembly Figure 9: Design of output drive type A Output mounting flange Stem nut with dog coupling Valve stem To adapt the actuators to available output drive types A with flanges F10 and F14 Information (year of manufacture: 2009 and earlier), an adapter is required.
  • Page 18: 4.3.1.2. Multi-Turn Actuator (With Output Drive Type A): Mount To Valve

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Assembly AC 01.2 Intrusive Drill and bore stem nut [1] and cut thread. Information: When fixing in the chuck, make sure stem nut runs true! Clean the machined stem nut [1].
  • Page 19: Output Drive Types B And E

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Assembly 10. Fasten screws [3] crosswise with a torque according to table. Table 8: Tightening torques for screws Threads Tightening torque [Nm] Strength class A2-80/A4 80 11.
  • Page 20: 4.3.2.1. Multi-Turn Actuator With Output Drive Types B: Mount To Valve/Gearbox

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Assembly AC 01.2 Intrusive Spigot at valve flanges should be loose fit. Information 4.3.2.1. Multi-turn actuator with output drive types B: mount to valve/gearbox Figure 13: Mounting output drive types B...
  • Page 21: Accessories For Assembly

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Assembly 4.4. Accessories for assembly 4.4.1. Stem protection tube for rising valve stem Figure 14: Assembly of the stem protection tube Protective cap for stem protection tube (fitted)
  • Page 22: Mounting Positions Of Local Controls

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Assembly AC 01.2 Intrusive 4.5. Mounting positions of local controls Figure 16: Mounting positions The mounting position of the local controls is implemented according to the order.
  • Page 23: Electrical Connection

    The pertaining wiring diagram/terminal plan (in German or English) is attached to the device in a weather-proof bag, together with these operation instructions. It can plan also be requested from AUMA (state order number, refer to name plate) or downloaded directly from the Internet (http://www.auma.com). Permissible networks Actuator controls (actuators) are suitable for use in TN and TT networks with directly earthed star point for mains voltage up to maximum 690 V AC.
  • Page 24 Thyristor B3 up to 5.5 kW 63 A (g/R) I²t<5,000A²s The AUMA power class (A1, B1, ...) is indicated on the actuator controls name plate Consider the motor starting current (I ) (refer to electrical data sheet) when selecting the circuit breaker. We recommend tripping characteristics D or K for circuit breakers in accordance with IEC 60947-2.
  • Page 25: Electrical Connection S/Sh (Auma Plug/Socket Connector)

    10 mm (solid) (flexible or solid) For some special motors, the connection of the power terminals (U1, V1, W1, U2, Information V2, W2) is not performed via the AUMA plug/socket connector but via a terminal board directly at the motor.
  • Page 26: Terminal Compartment : Open

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Electrical connection AC 01.2 Intrusive 5.2.1. Terminal compartment : open Figure 19: Open terminal compartment Cover (figure shows S version) Screws for cover O-ring Screws for socket carrier...
  • Page 27: Cable Connection

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Electrical connection 5.2.2. Cable connection Table 14: Terminal cross sections and terminal tightening torques Designation Terminal cross sections Tightening torques Power contacts 6 mm (flexible) 1.5 Nm...
  • Page 28: Terminal Compartment : Close

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Electrical connection AC 01.2 Intrusive 5.2.3. Terminal compartment : close Figure 22: Close terminal compartment Cover (figure shows S version) Screws for cover O-ring Screws for socket carrier...
  • Page 29: Accessories For Electrical Connection

    Versions with potentiometer in the actuator are not suitable. We recommend: AUMA cable set LSW1. If the AUMA cable set is not used: Use suitable flexible and screened connecting cables. When using connecting cables, e.g. of the heater or switch, requiring direct...
  • Page 30: Parking Frame

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Electrical connection AC 01.2 Intrusive 5.3.2. Parking frame Figure 24: Parking frame, example with S plug/socket connector and cover Parking frame for safe storage of a disconnected plug or cover.
  • Page 31: External Earth Connection

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Electrical connection 5.3.4. External earth connection Figure 26: Earth connection for multi-turn actuator External earth connection (U-bracket) for connection to equipotential compensation. Application Table 15:...
  • Page 32: Operation

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Operation AC 01.2 Intrusive Operation 6.1. Manual operation For purposes of setting and commissioning, in case of motor or power failure, the actuator may be operated manually. Manual operation is engaged by an internal change-over mechanism.
  • Page 33: Motor Operation

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Operation 6.2. Motor operation Perform all commissioning settings and the test run prior to motor operation. Valve damage due to incorrect basic setting! Prior to electrical operation of the actuator, the basic settings i.e. type of seating, torque and limit switching have to be completed.
  • Page 34: Actuator Operation From Remote

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Operation AC 01.2 Intrusive 6.2.2. Actuator operation from remote Risk of immediate actuator operation when switching on! Risk of personal injuries or damage to the valve If the actuator starts unexpectedly: Immediately turn selector switch to position 0 (OFF).
  • Page 35: Menu Layout And Navigation

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Operation Table 16: Important push button functions for menu navigation Push buttons Navigation sup- Functions port on display Up ▲ Change screen/selection Change values Enter figures from 0 to 9 Down ▼...
  • Page 36: User Level, Password

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Operation AC 01.2 Intrusive the push buttons on the local controls have not been operated within 10 minutes or by briefly pressing C When entering the ID within the main menu, screens can be displayed directly (without Direct display via ID clicking through).
  • Page 37: Password Change

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Operation Use push buttons Up ▲ Down ▼ to select figures 0 to 9. Confirm first digit of password via push button Repeat steps 1 and 2 for all further digits.
  • Page 38 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Operation AC 01.2 Intrusive Set selector switch to position 0 (OFF). Select main menu Press push button C Setup and hold it down for approx. 3 seconds.
  • Page 39: Indications

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Indications Indications 7.1. Indications during commissioning When switching on the power supply, all LEDs on the local controls illuminate for LED test approx. 1 second. This optical feedback indicates that the voltage supply is connected to the controls and all LEDs are operable.
  • Page 40: Feedback Indications From Actuator And Valve

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Indications AC 01.2 Intrusive Figure 40: Information in the status bar (top) Operation mode Error symbol (only for faults and warnings) ID number: S = Status page...
  • Page 41 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Indications Torque (S0002) The indication is only available if the actuator is equipped with an MWG (magnetic limit and torque transmitter). S0002 on the display indicates the torque applied at the actuator output.
  • Page 42: Status Indications According To Auma Classification

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Indications AC 01.2 Intrusive If the positioner is enabled and activated, the bar graph indication for E1 (position Setpoint control setpoint) is displayed. The direction of the operation command is displayed by an arrow above the bar graph indication.The figure below shows the operation command in direction CLOSE.
  • Page 43: Status Indications According To Namur Recommendation

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Indications Figure 49: Warnings For further information, please also refer to <Corrective action>. Not ready REMOTE (S0006) The S0006 display shows indications of the Not ready REMOTE group.
  • Page 44 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Indications AC 01.2 Intrusive For further information, please also refer to <Corrective action>. Function check (S0009) The S0009 indication shows function check indications according to NAMUR recommendation NE 107.
  • Page 45: Indication Lights Of Local Controls

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Indications 7.3. Indication lights of local controls Figure 56: Arrangement and signification of indication lights Marking with symbols (standard) Marking with figures 1 6 (option)
  • Page 46: Optional Indications

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Indications AC 01.2 Intrusive 7.4. Optional indications 7.4.1. Mechanical position indication via indicator mark Figure 57: Mechanical position indicator End position OPEN reached End position CLOSED reached...
  • Page 47: Signals (Output Signals)

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Signals (output signals) Signals (output signals) 8.1. Status signals via output contacts (digital outputs) Output contacts are used to send status signals (e.g. reaching the end positions, Characteristics selector switch position, faults...) as binary signals to the control room.
  • Page 48: Commissioning (Basic Settings)

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Commissioning (basic settings) AC 01.2 Intrusive Commissioning (basic settings) Set selector switch to position 0 (OFF). Information: The selector switch is not a mains switch. When positioned to 0 (OFF), the actuator cannot be operated.
  • Page 49: Switch Compartment: Open

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Commissioning (basic settings) Up ▲ Down ▼ to select user: User login Information: Required user level: Specialist (4) or higher The symbols have the following meaning: black triangle: ▶...
  • Page 50: Torque Switching: Set

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Commissioning (basic settings) AC 01.2 Intrusive 9.3. Torque switching: set Once the set torque is reached, the torque switches will be tripped (overload protection of the valve).
  • Page 51: End Position Closed (Black Section): Set

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Commissioning (basic settings) Figure 59: Setting elements for limit switching Black section: Setting spindle: End position CLOSED Pointer: End position CLOSED Mark: End position CLOSED is set...
  • Page 52: Intermediate Positions: Set

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Commissioning (basic settings) AC 01.2 Intrusive 9.5. Intermediate positions: set Actuators equipped with DUO limit switching contain two intermediate position switches. One intermediate position may be set for each running direction.
  • Page 53: Test Run

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Commissioning (basic settings) Press down and turn setting spindle [4] with screw driver in direction of the arrow and observe the pointer [5]: While a ratchet click is felt and heard, the pointer [5] moves 90°...
  • Page 54: Direction Of Rotation At Hollow Shaft/Stem: Check

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Commissioning (basic settings) AC 01.2 Intrusive 9.6.2. Direction of rotation at hollow shaft/stem: check Valve damage due to incorrect direction of rotation! If the direction of rotation is wrong, switch off immediately (press STOP).
  • Page 55: Reference Operation Position Feedback: Perform

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Commissioning (basic settings) Operate actuator using push buttons OPEN, STOP, CLOSE. The limit switching is set correctly if (default indication): the yellow indication light/LED1 is illuminated in end position CLOSED the green indication light/LED5 is illuminated in end position OPEN the indication lights go out after travelling into opposite direction.
  • Page 56: Commissioning (Optional Equipment Settings)

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Commissioning (optional equipment settings) AC 01.2 Intrusive Commissioning (optional equipment settings) 10.1. EWG 01.1 electronic position transmitter EWG 01.1 electronic position transmitter signals the remote position or the valve position.
  • Page 57: Measuring Range: Set

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Commissioning (optional equipment settings) 10.1.1. Measuring range: set For measuring range setting, voltage must be applied at the position transmitter. For output current verification, connect a test device for 0 20 mA to measurement points (+/ ) (for 2-wire systems, connecting a test device is imperatively required).
  • Page 58: Led End Position Signalling: Switch On/Off

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Commissioning (optional equipment settings) AC 01.2 Intrusive Information If the current value fluctuates (e.g. between 4.0 4.2mA), the <LED end position signalling> must be switched off for current adjustment.
  • Page 59: Rwg Electronic Position Transmitter

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Commissioning (optional equipment settings) Turn potentiometer [1] clockwise to the stop. End position CLOSED corresponds to 0 % End position OPEN corresponds to 100 % Turn potentiometer [1] slightly in opposite direction.
  • Page 60: Mechanical Position Indicator: Set

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Commissioning (optional equipment settings) AC 01.2 Intrusive Turn potentiometer [1] clockwise to the stop. Turn potentiometer [1] slightly in opposite direction. Turn potentiometer [2] clockwise until output current starts to increase.
  • Page 61: Corrective Action

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Corrective action Corrective action 11.1. Faults during operation/commissioning Table 24: Faults during operation/commissioning Fault Description/cause Remedy Mechanical position indicator cannot Reduction gearing is not suitable for turns/stroke Set gear stage of the reduction gearing.
  • Page 62 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Corrective action AC 01.2 Intrusive Table 25: Faults and warnings via status indications in the display Indication on display Description/cause Remedy S0001 Instead of the valve position, a status text is dis- For a description of the status texts, refer to Manual played.
  • Page 63 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Corrective action Warnings and Out of specification Indication on display Description/cause Remedy Wrn setpoint position Warning: Loss of signal setpoint position Check setpoint signal.
  • Page 64 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Corrective action AC 01.2 Intrusive Faults and Failure Indication on display Description/cause Remedy Torque fault OPEN Torque fault in direction OPEN Perform one of the following measures: Issue operation command in direction CLOSE.
  • Page 65 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Corrective action Faults and Failure Indication on display Description/cause Remedy DMF fault OPEN The torque in direction OPEN, measured at the Check DMF trip torque OP parameter.
  • Page 66: Fuses

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Corrective action AC 01.2 Intrusive 11.3. Fuses 11.3.1. Fuses within the actuator controls Fuses used F1/F2 Table 29: Primary fuses F1/F2 (for power supply unit) G fuse F1/F2 AUMA art.
  • Page 67: Motor Protection (Thermal Monitoring)

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Corrective action Loosen screws [1] and remove plug/socket connector [2]. Figure 67: Pull fuse holder [3] out of pin carrier, open fuse cover and replace old fuses by new ones.
  • Page 68 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Corrective action AC 01.2 Intrusive winding. Motor protection trips as soon as the max. permissible winding temperature has been reached. The actuator is switched off and the following signals are given: LED 3 (motor protection trippped) on the local controls is illuminated.
  • Page 69: Servicing And Maintenance

    Therefore, we recommend contacting our service. Only perform servicing and maintenance tasks when the device is switched off. AUMA AUMA offers extensive service such as servicing and maintenance as well as Service & Support customer product training. For the relevant contact addresses, please refer to <Addresses>...
  • Page 70: Maintenance

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Servicing and maintenance AC 01.2 Intrusive 12.2. Maintenance Lubrication In the factory, the gear housing is filled with grease. Grease change is performed during maintenance Generally after 4 to 6 years for modulating duty.
  • Page 71: Technical Data

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Technical data Technical data The following tables include standard and optional features. For detailed information Information on the customer-specific version, refer to the order-related data sheet. The technical data sheet can be downloaded from the Internet in both German and English at ht- tp://www.auma.com (please state the order number).
  • Page 72 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Technical data AC 01.2 Intrusive Features and functions Electrical connection Standard: AUMA plug/socket connector with screw-type connection Motor connection for some DC motors via separate motor terminal board...
  • Page 73 Resistant to vibration during start-up or for failures of the plant. However, a fatigue strength may not be derived from this. Indications apply to actuators with AUMA 3-phase AC motor and AUMA plug/socket connector. They are not valid in combination with gearboxes.
  • Page 74: Technical Data Actuator Controls

    The reversing contactors are designed for a lifetime of 2 million starts. For applications requiring a high number of starts, we recommend the use of thyristor units. For the assignment of AUMA power classes, please refer to Electrical data on actuator Control inputs...
  • Page 75 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Technical data Features and functions Control voltage/current consumption Standard: 24 V DC, current consumption: approx. 10 mA per input for control inputs Options: 48 V DC, current consumption: approx. 7 mA per input 60 V DC, current consumption: approx.
  • Page 76 Communication interface Required accessories: AUMA CDT (Commissioning and Diagnostic Tool for Windows-based PC) AUMA Assistant App (Commissioning and Diagnostic Tool for Android devices) Application functions Standard: Selectable type of seating, limit or torque seating for end position OPEN and end po-...
  • Page 77 Terminal compartment additionally sealed against interior of actuator controls (double sealed) According to AUMA definition, enclosure protection IP68 meets the following requirements: Depth of water: Maximum 8 m head of water Duration of continuous immersion in water: Maximum 96 hours Up to 10 operations during continuous immersion Modulating duty is not possible during continuous immersion.
  • Page 78 (MWG requires a separate data cable.) Programming software AUMA CDT (Commissioning and Diagnostic Tool for Windows-based PC) AUMA Assistant App (Commissioning and Diagnostic Tool for Android devices) Torque measurement flange DMF Accessory for torque measurement for SA/SAR 07.2 SA/SAR 16.2...
  • Page 79: Spare Parts

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Spare parts Spare parts 14.1. Multi-turn actuators SA 07.2 SA 16.2/SAR 07.2 SAR 16.2...
  • Page 80 AC 01.2 Intrusive Please state device type and our order number (see name plate) when ordering spare parts. Only original AUMA spare parts should be used. Failure to use original spare parts voids the warranty and exempts AUMA from any liability. Representation of spare parts may slightly vary from actual delivery.
  • Page 81: Ac 01.2 Actuator Controls

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Spare parts 14.2. AC 01.2 actuator controls...
  • Page 82 AC 01.2 Intrusive Please state device type and our order number (see name plate) when ordering spare parts. Only original AUMA spare parts should be used. Failure to use original spare parts voids the warranty and exempts AUMA from any liability. Representation of spare parts may slightly vary from actual delivery.
  • Page 83: Certificates

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Certificates Certificates Certificates are valid as from the indicated date of issue. Subject to changes without Information notice. The latest versions are attached to the device upon delivery and also available for download at http://www.auma.com.
  • Page 84 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive...
  • Page 85 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive...
  • Page 86: Index

    SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Index AC 01.2 Intrusive Index Earth connection Electrical connection 23, 72 Electronic position transmitter 56, 59 Accessories (electrical con- nection) Enclosure protection 8, 9, 9, 73, 77...
  • Page 87 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical AC 01.2 Intrusive Index Language in the display Packaging LED end position signalling Parking frame LEDs (indication lights) Password Lifetime Password change Limit switching 50, 54 Password entry...
  • Page 88 SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit - electromechanical Index AC 01.2 Intrusive Safety instructions Year of production Safety instructions/warnings Safety measures Safety standards Self-locking Self-retaining Serial number 8, 9, 10 Service Servicing Setpoint - indication on dis-...
  • Page 89: Addresses

    Europe AUMA Finland Oy AUMA-LUSA Representative Office, Lda. FI 02230 Espoo PT 2730-033 Barcarena Tel +358 9 5840 22 Tel +351 211 307 100 AUMA Riester GmbH & Co. KG auma@auma.fi geral@aumalusa.pt www.auma.fi Location Muellheim SAUTECH DE 79373 Muellheim AUMA France S.A.R.L.
  • Page 90 AUMA worldwide America AUMA Actuators (China) Co., Ltd. FLOWTORK TECHNOLOGIES CN 215499 Taicang CORPORATION AUMA Argentina Rep.Office Tel +86 512 3302 6900 PH 1550 Mandaluyong City AR Buenos Aires mailbox@auma-china.com Tel +63 2 532 4058 Tel +54 11 4737 9026 www.auma-china.com...
  • Page 91 AUMA worldwide...
  • Page 92 AUMA Riester GmbH & Co. KG P.O. Box 1362 DE 79373 Muellheim Tel +49 7631 809 - 0 Fax +49 7631 809 - 1250 info@auma.com www.auma.com Y004.751/003/en/1.18 For detailed information on AUMA products, refer to the Internet: www.auma.com...

This manual is also suitable for:

Sa 16.2Sar 07.2Sa 07.2

Table of Contents