Parameter index
Parameter name
Function
Bit
Value
* Default value is 0.
Parameter index
Parameter name
Function
Bit
Value
* The default value is "0," which means that the notification is disabled.
Parameter index
Parameter name
Function
Bit
Value
0x48 (energizing time)
Energizing time
Displays the accumulated energizing time of the electro pneumatic regulator.
Please note that the number indicates hours and is refreshed every hour.
Bit 31 to 0
If the Bit are 1111 1111 1111 1111 1111 1111 1111 1111, this indicates
approximately 4 billion hours.
0x49 (Notification setting of accumulated energizing time)
Notification setting of the accumulated energizing time
This function uses process data to notify the user that the accumulated
energizing time of the electro-pneumatic regulator reached the time set
with this function.
The default value is "0," which means no notification is output.
If a value is "1" or greater, the notification setting is enabled.
Bit 31 to 0
0
Setting the Bit to 1111 1111 1111 1111 1111 1111 1111 1111 sets it to
approximately 4 billion hours.
Setting the Bit to 0000 0000 0000 0000 0010 0010 0011 1000 sets it
to approximately 8,760 hours (equivalent to 1 year: 24 hours x 365
days).
0xA0 (Product number)
Product number
Displays the product number of the electro-pneumatic regulator.
BYTE 64 (Maximum)
The Bits 49 54 56 32 30 33 30 2D 49 4C 32 42 4E (hexadecimal
number) indicate "ITV2030-IL2BN."
(ASCII code)
- 20 -