Product individual parameters
Index
Access
(decimal
Subindex
number)
0x41
0
R/W
(65)
0x42
0
R/W
(66)
0x43
0
R/W
(67)
0x46
0
R/W
(70)
0x47
0
R/W
(71)
0x48
0
(72)
0x49
0
R/W
(73)
0xA0
0
(160)
*1: R means Read and W means Write.
*2: Refer to the table below for the symbol.
Data type
Symbol
(IO-Link
standard)
U8
UIntegerT
U16
U32
StringT
STR64
* 3 " Y" indicates that the parameter setting data is saved to the master, and "N" indicates that
the parameter is not saved.
*4 Cannot be set to a value where "maximum pressure - minimum pressure < 10%"
Parameter
*1
name
Hold/clear
Gain
Sensitivity
Minimum
pressure
Maximum
pressure
Accumulated
R
energizing
time
Notification
setting of the
accumulated
energizing
time
Product
R
number
Data length
Bit [BYTE]
8 [1]
16 [2]
32 [4]
Data
Data
Initial
type
storage
value
*2
U8
{0}
U8
{9}
U8
{2}
U16
{0}
U16
{4095}
U32
{0}
U32
{0}
{Produc
STR6
t
4
number
}
Unsigned integer (unsigned integer)
Up to 64-BYTE character string
-
(String)
- 15 -
Details
*3
Pressure control setting
when an IO-Link
communication error occurs.
Y
When {0} is set, output
pressure is cleared. When
{1} is set, output pressure is
held.
The gain for the
electro-pneumatic regulator
Y
can be adjusted in the range
from 0 to 16.
The sensitivity of the
electro-pneumatic regulator
Y
can be adjusted in the range
from 0 to 8.
Set setting pressure zero
point.
Y
(can be set in the range from
0 to 90%. *4)
Set setting pressure span
point.
Y
(can be set in the range from
10 to 120%. *4)
Displays accumulated
Y
energizing time.
Set notification of the
Y
accumulated energizing
time.
Displays the product
N
number.
Description