System command (Index 2)
In the ISDU index 0x002 System Command, the command shown in the table below will be
issued.
The button of each system command is displayed on the IO-Link setting tool (excluding
"Param Download Store").
Click the button to send the system command to the E-P regulator.
This is system command configuration.
Command
(decimal
number)
0x05
(5)
0x80
(128)
0x81
(129)
0x82
Restore factory settings*2
(130)
0xA0
(160)
*1 to 3: Same definition as button operation.
Command name
Param Download Store
Device reset
Application reset*1
Zero Clear*3
Back-up of the parameter set data.
When the electro-pneumatic regulator
receives a command, it starts uploading
the parameter settings to the master.
Corresponds to power ON/OFF. Restart
the system.
Reset function
Reset the minimum / maximum value
and key lock function.
Initialization function.
All parameter settings are returned to
the factory settings. All settings are
cleared.
Execute a zero-clear function.